Test of a single module of the J-PET scanner based on plastic scintillators
arXiv:1407.7395 · doi:10.1016/j.nima.2014.07.052
Abstract
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.
12 pages, 6 figures; Updated with editorial corrections related to publication in NIM A
References in corpus (1)
Cited by in corpus (31)
- Positronium imaging with the novel multiphoton PET scanner
- Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
- Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
- Positronium Physics and Biomedical Applications
- Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
- A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
- Discrete symmetries tested at 10 precision using linear polarization of photons from positronium annihilations
- Analysis framework for the J-PET scanner
- Multiple scattering and accidental coincidences in the J-PET detector simulated using GATE package
- Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
- Multi-photon time-of-flight MLEM application for the positronium imaging in J-PET
- Decoherence puzzle in measurements of photons originating from electron-positron annihilation
- A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
- Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
- Commissioning of the J-PET detector for studies of decays of positronium atoms
- Development of novel plastic scintillators based on polyvinyltoluene for the hybrid J-PET/MR tomograph
- J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
- Towards Time Reversal Symmetry Test with o-Ps Decays using the J-PET detector
- TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
- First Positronium Lifetime Imaging using Mn and Co with a plastic-based PET scanner
- Development of J-PEM for breast cancer detection and diagnosis using positronium imaging
- Introduction of total variation regularization into filtered backprojection algorithm
- Search for the Charge symmetry forbidden decays of electron-positron bound state using the J-PET detector
- First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target
- Quantum Entanglement Degree, Mean Positronium Lifetime, and the / Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia -- Concept, Challenges, and Predictions
- Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
- Measurement of the CKM angle at Belle II