Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
arXiv:1602.02058 · doi:10.1088/0031-9155/61/5/2025
Abstract
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of 0.170 ns for 15 cm axial field-of-view (AFOV) and 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.
arXiv commentTo be published in Phys. Med. Biol. (26 pages, 17 figures)
References in corpus (9)
- Test of a single module of the J-PET scanner based on plastic scintillators
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
- Novel detector systems for the Positron Emission Tomography
- Multiple scattering and accidental coincidences in the J-PET detector simulated using GATE package
- TOF-PET detector concept based on organic scintillators
- Simulations of gamma quanta scattering in a single module of the J-PET detector
Cited by in corpus (36)
- Feasibility study of the positronium imaging with the J-PET tomograph
- Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
- Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
- Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
- Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
- A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
- Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
- Witnessing Entanglement In Compton Scattering Processes Via Mutually Unbiased Bases
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
- Genuine Multipartite Entanglement in the -Photon Decay of Positronium
- Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
- The J-PET detector -- a tool for precision studies of ortho-positronium decays
- Probing entanglement in Compton interactions
- Multi-photon time-of-flight MLEM application for the positronium imaging in J-PET
- Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
- Proton light yield of fast plastic scintillators for neutron imaging
- Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
- Analysis procedure of the positronium lifetime spectra for the J-PET detector
- Comparing bound entanglement of bell diagonal pairs of qutrits and ququarts
- Almost complete solution for the NP-hard separability problem of Bell diagonal qutrits
- Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
- Development of novel plastic scintillators based on polyvinyltoluene for the hybrid J-PET/MR tomograph
- J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
- Potential for biomedical applications of Positron Annihilation Lifetime Spectroscopy (PALS)
- A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
- Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
- Time calibration of the J-PET detector
- TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
- Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
- Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
- Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
- Status and Prospects of Discrete Symmetries Tests in Positronium Decays with the J-PET Detector
- Studies Of The Polarization Of Gamma Photons Originating From The Decay of Positronium Atoms
- Quantifying Quantum Correlations in Annihilation Photon Pairs under Compton Scattering