most citedTest of a single module of the J-PET scanner based on plastic scintillators

219 citations · 1.5k across the 45 of their papers we have counts for

collaborators

46 papers

physics.ins-det2020★ 17 cited

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

P. Moskal, T. Bednarski, Sz. Niedzwiecki +36

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a…

physics.ins-det2017★ 72 cited

Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement

M. Pałka, P. Strzempek, G. Korcyl +29

In this article it is presented an FPGA based ulti-oltage hreshold (MVT) system which allows of sampling fast signals ( ns rising and falling edge) in both voltage an…

physics.ins-det2017★ 32 cited

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

L. Raczyński, W. Wiślicki, W. Krzemień +31

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularizatio…

physics.ins-det2016★ 90 cited

Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

J. Smyrski, D. Alfs, T. Bednarski +29

We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons esca…

physics.ins-det2016★ 71 cited

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D. Kamińska, A. Gajos, E. Czerwiński +26

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PE…

physics.ins-det2016★ 121 cited

Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

P. Moskal, O. Rundel, D. Alfs +27

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability f…

physics.ins-det2016★ 63 cited

Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

A. Gajos, D. Kamińska, E. Czerwiński +28

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded…

physics.med-ph2016★ 27 cited

Scatter fraction of the J-PET tomography scanner

P. Kowalski, W. Wiślicki, L. Raczyński +24

A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the…

physics.ins-det2016★ 39 cited

Sampling FEE and Trigger-less DAQ for the J-PET Scanner

G. Korcyl, D. Alfs, T. Bednarski +29

In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general detector readout chain is const…

physics.ins-det2016★ 4 cited

Beam profile investigation of the new collimator system for the J-PET detector

E. Kubicz, M. Silarski, A. Wieczorek +23

Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and…

nucl-ex2016★ 60 cited

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

P. Moskal, D. Alfs, T. Bednarski +24

The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Be…

physics.ins-det2015★ 6 cited

Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector

D. Kamińska, T. Bednarski, P. Białas +24

In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests o…

q-bio.OT2015★ 15 cited

Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy

E. Kubicz, B. Jasińska, B. Zgardzińska +26

Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps)…

physics.ins-det2015★ 9 cited

Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance

N. G. Sharma, M. Silarski, T. Bednarski +24

The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detec…

physics.ins-det2015★ 4 cited

PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

A. Wieczorek, B. Zgardzińska, B. Jasińska +25

The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated us…

physics.ins-det2015★ 5 cited

Processing optimization with parallel computing for the J-PET tomography scanner

W. Krzemień, M. Bała, T. Bednarski +27

The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time propertie…

physics.ins-det2015★ 2 cited

Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

L. Raczynski, P. Moskal, P. Kowalski +24

Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast det…

physics.med-ph2015★ 12 cited

3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

Artur Słomski, Zbigniew Rudy, Tomasz Bednarski +23

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of m…

physics.ins-det2015★ 26 cited

Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

Łukasz Kapłon, Andrzej Kochanowski, Marcin Molenda +24

This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing pro…

physics.ins-det2015★ 21 cited

Multiple scattering and accidental coincidences in the J-PET detector simulated using GATE package

P. Kowalski, P. Moskal, W. Wiślicki +28

Novel Positron Emission Tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device,…

physics.ins-det2015★ 28 cited

Analysis framework for the J-PET scanner

W. Krzemień, A. Gajos, A. Gruntowski +28

J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. I…

physics.ins-det2015★ 10 cited

Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals

P. Moskal, N. G. Sharma, M. Silarski +28

In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors…

physics.ins-det2015★ 6 cited

GPU accelerated image reconstruction in a two-strip J-PET tomograph

P. Białas, J. Kowal, A. Strzelecki +26

We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.

physics.ins-det2015★ 15 cited

A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

A. Wieczorek, P. Moskal, Sz. Niedźwiecki +30

For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In thi…