Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
arXiv:1612.08571 · doi:10.1016/j.nima.2017.01.045
Abstract
We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of wavelength-shifting (WLS) strips. Using a test set-up comprising a BC-420 scintillator bar and an~array of sixteen BC-482A WLS strips we achieved a spatial resolution of~5\,mm~() for annihilation photons from a Na isotope. The studied method can be used to improve the spatial resolution of a plastic-scintillator-based PET scanner which is being developed by the J-PET collaboration.
13 pages, 8 figures; Submitted to Nuclear Instruments and Methods in Physics Research Section A
References in corpus (6)
- Test of a single module of the J-PET scanner based on plastic scintillators
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- Simultaneous reconstruction of scintillation light and ionization charge produced by 511 keV photons in liquid xenon : potential application to PET
Cited by in corpus (10)
- Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
- Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
- Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
- TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
- Development of J-PEM for breast cancer detection and diagnosis using positronium imaging
- Introduction of total variation regularization into filtered backprojection algorithm
- Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
- Measurement of the CKM angle at Belle II
- Search for the Charge symmetry forbidden decays of electron-positron bound state using the J-PET detector