activity
20052025
most citedTest of a single module of the J-PET scanner based on plastic scintillators

219 citations · 1.4k across the 42 of their papers we have counts for

collaborators

43 papers

hep-ex2025

P371 Experiment at CERN -- quest for polarized antiprotons

M. Zielinski, D. Grzonka, G. Khatri +6

Polarization effects in the production of antiprotons at the CERN PS beam line T11 at 3.5 GeV/c have been investigated within the P371 experiment. These effects, if found to be sig…

nucl-ex2020★ 10 cited

Search for the mesic He in the reaction with the WASA-at-COSY facility

P. Adlarson, W. Augustyniak, M. Bashkanov +80

The excitation function for the reaction has been measured by WASA-at-COSY experiment with the aim of searching for $^{3}\hspace{-0.03cm}\mbox{He}$-…

nucl-ex2019★ 9 cited

Search for eta mesic 3He with the WASA-at-COSY facility in the pd-> 3He 2gamma and pd-> 3He 6gamma reactions

P. Adlarson, W. Augustyniak, W. Bardan +81

We report on the experimental search for the bound state of an meson and $^{3}\hspace{-0.03cm}\mbox{He}$ nucleus performed using the WASA-at-COSY detector setup. In order to se…

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

nucl-ex2018★ 3 cited

On the Production of an Isotensor Dibaryon in the Reaction

P. Adlarson, W. Augustyniak, W. Bardan +81

Exclusive measurements of the quasi-free reaction have been performed by means of collisions at = 1.2 GeV using the WASA detector setup at COSY. Total…

physics.ins-det2017★ 116 cited

J-PET: a new technology for the whole-body PET imaging

S. Niedźwiecki, P. Białas, C. Curceanu +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three…

physics.ins-det2017★ 14 cited

Analysis procedure of the positronium lifetime spectra for the J-PET detector

K. Dulski, B. Zgardzinska, P. Bialas +30

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…

physics.ins-det2017★ 3 cited

Time calibration of the J-PET detector

M. Skurzok, M. Silarski, D. Alfs +32

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the firs…

nucl-ex2017★ 2 cited

Spin dependence of η meson production in proton-proton collisions close to threshold

P. Adlarson, W. Augustyniak, W. Bardan +88

Taking advantage of the high acceptance and axial symmetry of the WASA-at-COSY detector, and the high degree of the polarized proton beam of COSY, the reaction pp{\to} ppη has been…

nucl-ex2017★ 3 cited

Importance of d-wave contributions in the charge symmetry breaking reaction

P. Adlarson, W. Augustyniak, W. Bardan +89

This letter reports a first quantitative analysis of the contribution of higher partial waves in the charge symmetry breaking reaction using the WASA-at-C…

physics.ins-det2017★ 72 cited

Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement

M. Pałka, P. Strzempek, G. Korcyl +29

In this article it is presented an FPGA based ulti-oltage hreshold (MVT) system which allows of sampling fast signals ( ns rising and falling edge) in both voltage an…

physics.ins-det2017★ 32 cited

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

L. Raczyński, W. Wiślicki, W. Krzemień +31

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularizatio…

physics.ins-det2016★ 90 cited

Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

J. Smyrski, D. Alfs, T. Bednarski +29

We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons esca…

nucl-ex2016★ 37 cited

Search for eta-mesic 4He in the dd->3He n pi0 and dd->3He p pi- reactions with the WASA-at-COSY facility

P. Adlarson, W. Augustyniak, W. Bardan +90

The search for 4He-eta bound states was performed with the WASA-at-COSY facility via the measurement of the excitation function for the dd->3He n pi0 and dd->3He p pi- processes. T…

nucl-ex2016★ 20 cited

Measurement of the Dalitz plot distribution

COSY Collaboration, P. Adlarson, W. Augustyniak +93

Using the production reactions $pd\to {}^3\mbox{He}\,ω$ and , the Dalitz plot distribution for the decay is studied with the WASA detector at COSY, ba…

physics.ins-det2016★ 71 cited

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D. Kamińska, A. Gajos, E. Czerwiński +26

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PE…

nucl-ex2016★ 3 cited

Determination of the analysing power for the reaction using WASA-at-COSY detector system

I. Schaetti-Ozerianska, P. Moskal, M. Zielinski

We report on the measurement of the analyzing power for the (vec)pp->ppeta reaction with beam momenta of 2026 MeV/c and 2188 MeV/c performed with the WASA-at-COSY detector at the C…

nucl-ex2016★ 17 cited

Search for an Isospin I =3 Dibaryon

P. Adlarson, W. Augustyniak, W. Bardan +91

Various theoretical calculations based on QCD or hadronic interactions predict that in addition to the recently observed dibaryon resonance with there…

physics.ins-det2016★ 63 cited

Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

A. Gajos, D. Kamińska, E. Czerwiński +28

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded…

nucl-ex2016★ 60 cited

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

P. Moskal, D. Alfs, T. Bednarski +24

The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Be…

nucl-ex2015★ 18 cited

Measurements of Branching Ratios for Decays into Charged Particles

P. Adlarson, W. Augustyniak, W. Bardan +96

The WASA-at-COSY experiment has collected events with -mesons produced via the reaction at . Usi…

hep-ex2015

Determination of the polarization in the reaction with WASA-at-COSY detector

I. Schatti-Ozerianska, P. Moskal, M. Zielinski

The dynamics of -meson production and the interaction of -mesons with nucleons can be studied using the reaction via measurements of the analyzing power $A_…

nucl-ex2014★ 76 cited

Measurement of the Reaction in Search for the Recently Observed Resonance

P. Adlarson, W. Augustyniak, W. Bardan +99

Exclusive measurements of the quasi-free reaction have been performed by means of collisions at = 2.27 GeV using the WASA detector setup at COSY. Total…

physics.ins-det2014★ 219 cited

Test of a single module of the J-PET scanner based on plastic scintillators

P. Moskal, Sz. Niedźwiecki, T. Bednarski +27

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge…