most citedTest of a single module of the J-PET scanner based on plastic scintillators

219 citations · 1.4k across the 42 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

10 papers · 1 filter

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

physics.ins-det2017★ 116 cited

J-PET: a new technology for the whole-body PET imaging

S. Niedźwiecki, P. Białas, C. Curceanu +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three…

physics.ins-det2017★ 14 cited

Analysis procedure of the positronium lifetime spectra for the J-PET detector

K. Dulski, B. Zgardzinska, P. Bialas +30

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…

physics.ins-det2017★ 3 cited

Time calibration of the J-PET detector

M. Skurzok, M. Silarski, D. Alfs +32

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the firs…

physics.ins-det2017★ 72 cited

Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement

M. Pałka, P. Strzempek, G. Korcyl +29

In this article it is presented an FPGA based ulti-oltage hreshold (MVT) system which allows of sampling fast signals ( ns rising and falling edge) in both voltage an…

physics.ins-det2017★ 32 cited

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

L. Raczyński, W. Wiślicki, W. Krzemień +31

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularizatio…

physics.ins-det2016★ 90 cited

Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

J. Smyrski, D. Alfs, T. Bednarski +29

We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons esca…

physics.ins-det2016★ 71 cited

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D. Kamińska, A. Gajos, E. Czerwiński +26

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PE…

physics.ins-det2016★ 63 cited

Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

A. Gajos, D. Kamińska, E. Czerwiński +28

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded…

physics.ins-det2014★ 219 cited

Test of a single module of the J-PET scanner based on plastic scintillators

P. Moskal, Sz. Niedźwiecki, T. Bednarski +27

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge…