Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
arXiv:1706.00924 · doi:10.1088/1361-6560/aa7005
Abstract
In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built out from 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results, obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are consistent.
arXiv comment25 pages, 11 figures
References in corpus (10)
- Test of a single module of the J-PET scanner based on plastic scintillators
- Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
- A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
- Calibration of photomultipliers gain used in the J-PET detector
- Simulations of gamma quanta scattering in a single module of the J-PET detector
- PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Cited by in corpus (11)
- Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- The J-PET detector -- a tool for precision studies of ortho-positronium decays
- Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
- Analysis procedure of the positronium lifetime spectra for the J-PET detector
- J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
- Potential for biomedical applications of Positron Annihilation Lifetime Spectroscopy (PALS)
- Time calibration of the J-PET detector
- Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
- Status and Prospects of Discrete Symmetries Tests in Positronium Decays with the J-PET Detector
- Studies Of The Polarization Of Gamma Photons Originating From The Decay of Positronium Atoms