activity
20112026
most citedTest of a single module of the J-PET scanner based on plastic scintillators

219 citations · 3.2k across the 121 of their papers we have counts for

collaborators

124 papers

nucl-ex2026

-QCD; Proposal for Experiments at the GSI Pion Beam Facility

HADES Collaboration, R. Abou Yassine, J. Adamczewski-Musch +127

We propose to investigate the dynamics of hadronic matter in the strong QCD regime using the pion-beam facility at GSI in conjunction with HADES. This program will study hadron phy…

hep-ex2026

Measurement of Differential Cross Sections and Integrated Luminosity using Proton-Proton Elastic Scattering with HADES at T = 4.53 GeV and T = 1.60 GeV

HADES Collaboration, R. Abou Yassine, J. Adamczewski-Musch +125

This work presents an investigation of elastic proton-proton scattering based on data collected with the recently upgraded HADES detector using beams of protons with kinetic energi…

physics.med-ph2026

First-in-human quantum entanglement imaging

Pawel Moskal, Deepak Kumar, Sushil Sharma +37

Annihilation photons are quantum-entangled in polarization, a phenomenon that has not been exploited in medical diagnostics so far. We present the first in vivo imaging of the degr…

physics.ins-det2026

Demonstrating CBM Capabilities by Baryon Reconstruction in Ni+Ni Collisions with the mCBM Experiment at SIS18 of GSI/FAIR

CBM Collaboration, A. Agarwal, Z. Ahammed +338

The Compressed Baryonic Matter (CBM) experiment at the upcoming Facility for Antiproton and Ion Research (FAIR) is a high-rate fixed-target experiment designed to investigate nucle…

physics.med-ph2026★ 1 cited

First ex-vivo positronium imaging of tissues with modular J-PET scanner using Sc radionuclide

Karol Kubat, Manish Das, Sushil Sharma +41

This study presents the first ex-vivo positronium imaging of human tissues using the modular J-PET scanner with the Sc radionuclide. The Sc isotope was produced via t…

physics.med-ph2026

Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs

Szymon Parzych, Szymon Niedźwiecki, Ermias Yitayew Beyene +39

Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High s…

physics.med-ph2025★ 2 cited

First Positronium Lifetime Imaging using Mn and Co with a plastic-based PET scanner

Manish Das, Sushil Sharma, Ermias Yitayew Beyene +45

Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. In this work, we rep…

nucl-ex2025

Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector

N. Chug, S. D. Bass, E. Y. Beyene +40

A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitiv…

physics.med-ph2025★ 6 cited

First positronium imaging using Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Manish Das, Sushil Sharma, Aleksander Bilewicz +41

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties…

physics.app-ph2024

Nanoporosity imaging by positronium lifetime tomography

K. Dulski, E. Beyene, N. Chug +25

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the…

physics.med-ph2024

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

M. Dadgar, S. Parzych, F. Tayefi Ardebili +29

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-ba…

physics.ins-det2024★ 12 cited

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

L. Kaplon, J. Baran, N. Chug +31

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…

hep-ph2024★ 31 cited

Discrete symmetries tested at 10 precision using linear polarization of photons from positronium annihilations

Paweł Moskal, Eryk Czerwiński, Juhi Raj +38

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of…

physics.ins-det2023

Comparison of readout systems for high-rate silicon photo-multiplier applications

M. L. Wong, M. Kołodziej, K. Briggl +11

Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily ava…

nucl-ex2023

Inclusive ee production in collisions of pions with protons and nuclei in the second resonance region of baryons

R. Abou Yassine, J. Adamczewski-Musch, O. Arnold +125

Inclusive ee production has been studied with HADES in + p, + C and reactions, using the GSI pion beam at = 1.49 GeV. Inva…

physics.ins-det2023

Feasibility studies for imaging ee annihilation with modular multi-strip detectors

S. Sharma, L. Povolo, S. Mariazzi +41

Studies based on imaging the annihilation of the electron (e) and its antiparticle positron (e) open up several interesting applications in nuclear medicine and fundame…

physics.med-ph2023

Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

Meysam Dadgar, Szymon Parzych, Jakub Baran +28

Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and…

physics.med-ph2023

Feasibility of the J-PET to monitor range of therapeutic proton beams

Jakub Baran, Damian Borys, Karol Brzeziński +40

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring.…

nucl-ex2023★ 1 cited

Hadron Production and Propagation in Pion-Induced Reactions on Nuclei

R. Abou Yassine, J. Adamczewski-Musch, O. Arnold +125

Hadron production (, proton, , , ) in and collisions is investigated at an incident pion beam momentum of $1.7~\mathrm…

physics.med-ph2023★ 3 cited

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

R. Y. Shopa, J. Baran, K. Klimaszewski +32

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (T…

nucl-ex2023

Investigation of the Production Mechanism in p(3.5 GeV)+p Collisions

R. Abou Yassine, O. Arnold, M. Becker +88

The production of hyperons in proton proton collisions at a beam kinetic energy of 3.5 GeV impinging on a liquid hydrogen target was investigated using data collected with th…

nucl-ex2023

Production of hydrogen isotopes and charged pions in p (3.5 GeV) + Nb reactions

R. Abou Yassine, O. Arnold, M. Becker +85

The double differential production cross sections, , for hydrogen isotopes and charged pions in the reaction of p + Nb at 3.5 GeV proton beam energy have been measured b…

physics.ins-det2023★ 6 cited

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

S. Sharma, J. Baran, R. S. Brusa +33

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…

physics.med-ph2022★ 2 cited

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Jakub Baran, Wojciech Krzemien, Lech Raczyński +31

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods…