Calibration of photomultipliers gain used in the J-PET detector
T. Bednarski, E. Czerwiński, P. Moskal +27
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electr…
Simulations of gamma quanta scattering in a single module of the J-PET detector
K. Szymański, P. Moskal, T. Bednarski +27
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed…
Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators
J. Smyrski, P. Moskal, T. Bednarski +23
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this me…
A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
M. Pałka, T. Bednarski, P. Białas +23
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic…
J-PET analysis framework for the prototype TOF-PET detector
W. Krzemień, M. Silarski, K. Stola +25
Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruc…
A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays
M. Silarski, E. Czerwiński, T. Bednarski +23
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. Na or Ge, which are placed or rotate…
System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector
P. Białas, J. Kowal, A. Strzelecki +22
Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to eac…
Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators
L. Raczyński, P. Kowalski, T. Bednarski +22
Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random…
The Straw Tube Trackers of the PANDA Experiment
P. Gianotti, V. Lucherini, E. Pace +35
The PANDA experiment will be built at the FAIR facility at Darmstadt (Germany) to perform accurate tests of the strong interaction through bar pp and bar pA annihilation's studies.…
STRIP-PET: a novel detector concept for the TOF-PET scanner
P. Moskal, T. Bednarski, P. Białas +22
We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is ba…
TOF-PET detector concept based on organic scintillators
P. Moskal, T. Bednarski, P. Białas +22
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction…