A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
arXiv:1311.6127 · doi:10.1515/bams-2013-0104
Abstract
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of 10ps (rms) and thus enables sampling of signals in a voltage domain.
Submitted to Bio-Algorithms and Med.-Systems (6 pages, 6 figures)
Cited by in corpus (20)
- Test of a single module of the J-PET scanner based on plastic scintillators
- Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
- Analysis framework for the J-PET scanner
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
- A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
- Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals
- Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
- Development of novel plastic scintillators based on polyvinyltoluene for the hybrid J-PET/MR tomograph
- Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
- GPU accelerated image reconstruction in a two-strip J-PET tomograph
- Beam profile investigation of the new collimator system for the J-PET detector
- Observational demonstration of a low-cost fast Fourier transform spectrometer with a delay-line-based ramp-compare ADC implemented on FPGA
- First Positronium Lifetime Imaging using Mn and Co with a plastic-based PET scanner
- Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument
- Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts