activity
19972020
most citedPhysics Performance Report for PANDA: Strong Interaction Studies with Antiprotons

263 citations · 3.7k across the 105 of their papers we have counts for

collaborators

106 papers

hep-ex2020★ 7 cited

Differential Cross Sections for Neutron-Proton Scattering in the Region of the Dibaryon Resonance

P. Adlarson, W. Augustyniak, W. Bardan +102

Differential cross sections have been extracted from exclusive and kinematically complete high-statistics measurements of quasifree polarized scattering performed in the…

physics.ins-det2019★ 2 cited

Technical Design Report for the PANDA Endcap Disc DIRC

Panda Collaboration, F. Davi, W. Erni +460

PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and I…

physics.ins-det2019★ 1 cited

Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

N. Krawczyk, B. C. Hiesmayr, C. Curceanu +31

J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such…

physics.ins-det2018★ 55 cited

Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector

P. Moskal, N. Krawczyk, B. C. Hiesmayr +31

J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scatter…

physics.ins-det2018★ 14 cited

Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

K. Dulski, C. Curceanu, E. Czerwiński +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for s…

physics.ins-det2018★ 3 cited

A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

J. Raj, A. Gajos, C. Curceanu +31

The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an…

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

physics.ins-det2018★ 96 cited

Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

G. Korcyl, P. Białas, C. Curceanu +36

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no…

nucl-ex2018★ 1 cited

Backward single-pion production in the reaction with WASA-at-COSY

P. Adlarson, W. Augustyniak, W. Bardan +89

New data on the production of single neutral pions in the reaction are presented. For fifteen proton beam momenta between $p_p=1.60\;\textrm{GeV…

physics.ins-det2018★ 1 cited

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

A. Gajos, C. Curceanu, E. Czerwiński +29

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The…

physics.med-ph2018★ 4 cited

Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner

R. Masełek, W. Krzemien, K. Klimaszewski +31

The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is inve…

nucl-ex2018★ 16 cited

An Isotensor Dibaryon in the Reaction?

P. Adlarson, W. Augustyniak, W. Bardan +81

Exclusive measurements of the quasi-free reaction have been carried out at WASA@COSY by means of collisions at = 1.2 GeV. Total and differential cross…

nucl-ex2018★ 3 cited

On the Production of an Isotensor Dibaryon in the Reaction

P. Adlarson, W. Augustyniak, W. Bardan +81

Exclusive measurements of the quasi-free reaction have been performed by means of collisions at = 1.2 GeV using the WASA detector setup at COSY. Total…

hep-ex2018★ 9 cited

Search for violation in the decay with WASA-at-COSY

P. Adlarson, W. Augustyniak, W. Bardan +90

We report on the investigation of the rare decay which is of interest to study both violation in the electromagnetic interaction and to…

nucl-ex2018★ 11 cited

Total and differential cross sections of -production in proton-deuteron fusion for excess energies between and

P. Adlarson, W. Augustyniak, W. Bardan +90

New data on both total and differential cross sections of the production of mesons in proton-deuteron fusion to in the excess energy region $13.6\;\text{MeV}…

physics.med-ph2017★ 42 cited

Human Tissues Investigation Using PALS Technique

B. Jasińska, B. Zgardzińska, G. Chołubek +34

Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant dif…

physics.ins-det2017★ 12 cited

Commissioning of the J-PET detector for studies of decays of positronium atoms

E. Czerwiński, K. Dulski, P. Białas +29

The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positr…

physics.med-ph2017★ 1 cited

Introduction of total variation regularization into filtered backprojection algorithm

L. Raczyński, W. Wiślicki, K. Klimaszewski +30

In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of t…

physics.ins-det2017★ 116 cited

J-PET: a new technology for the whole-body PET imaging

S. Niedźwiecki, P. Białas, C. Curceanu +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three…

physics.ins-det2017★ 5 cited

Three-dimensional image reconstruction in J-PET using Filtered Back Projection method

R. Y. Shopa, K. Klimaszewski, P. Kowalski +30

We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of…

physics.ins-det2017★ 14 cited

Analysis procedure of the positronium lifetime spectra for the J-PET detector

K. Dulski, B. Zgardzinska, P. Bialas +30

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…

physics.ins-det2017★ 3 cited

Time calibration of the J-PET detector

M. Skurzok, M. Silarski, D. Alfs +32

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the firs…

nucl-ex2017★ 2 cited

Spin dependence of η meson production in proton-proton collisions close to threshold

P. Adlarson, W. Augustyniak, W. Bardan +88

Taking advantage of the high acceptance and axial symmetry of the WASA-at-COSY detector, and the high degree of the polarized proton beam of COSY, the reaction pp{\to} ppη has been…

nucl-ex2017★ 3 cited

Importance of d-wave contributions in the charge symmetry breaking reaction

P. Adlarson, W. Augustyniak, W. Bardan +89

This letter reports a first quantitative analysis of the contribution of higher partial waves in the charge symmetry breaking reaction using the WASA-at-C…