Analysis framework for the J-PET scanner
arXiv:1503.00465 · doi:10.12693/APhysPolA.127.1491
Abstract
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The Framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
6 pages, 1 figure
References in corpus (11)
- Physics with the KLOE-2 experiment at the upgraded DANE
- Test of a single module of the J-PET scanner based on plastic scintillators
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- Determination of the eta'-proton scattering length in free space
- Search for the eta-mesic 4He with WASA-at-COSY detector
- A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
- 3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm
- J-PET analysis framework for the prototype TOF-PET detector
- Database and data structure for the novel TOF-PET detector developed for J-PET project
- System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector
- Computing support for advanced medical data analysis and imaging
Cited by in corpus (16)
- Feasibility study of the positronium imaging with the J-PET tomograph
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
- Sampling FEE and Trigger-less DAQ for the J-PET Scanner
- J-PET Framework: Software platform for PET tomography data reconstruction and analysis
- Overview of the software architecture and data flow for the J-PET tomography device
- Overview of the software architecture and data flow for the J-PET tomography device
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
- Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
- Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
- Time calibration of the J-PET detector
- A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
- Investigations of fundamental symmetries with the electron-positron systems
- Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
- Studies Of The Polarization Of Gamma Photons Originating From The Decay of Positronium Atoms
- Test of Lightguides for the J-PET Detector