Overview of the software architecture and data flow for the J-PET tomography device
arXiv:1508.02451 · doi:10.5506/APhysPolB.47.561
Abstract
Modern TOF-PET scanner systems require high-speed computing resources for efficient data processing, monitoring and image reconstruction. In this article we present the data flow and software architecture for the novel TOF-PET scanner developed by the J-PET collaboration. We discuss the data acquisition system, reconstruction framework and image reconstruction software. Also, the concept of computing outside hospitals in the remote centers such as Świerk Computing Centre in Poland is presented.
8 pages, 2 figures
References in corpus (18)
- Test of a single module of the J-PET scanner based on plastic scintillators
- Indication of a deeply bound compact K-pp state formed in the pp -> p Lambda K+ reaction at 2.85 GeV
- Modification of the -Meson Lifetime in Nuclear Matter
- Partial Wave Analysis of the Reaction to Search for the "" Bound State
- Photoproduction of pi0-mesons from nuclei
- Measurement of the in-medium phi-meson width in proton-nucleus collisions
- Determination of the η'-nucleus optical potential
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Determination of the eta'-proton scattering length in free space
- The Near-Threshold Production of Phi Mesons in pp Collisions
- Photoproduction of the meson off the proton near threshold
- Precision measurement of the quasi-free pn->dphi reaction close to threshold
- Photoproduction of ω Mesons off the Proton
- Study of the and reactions close to threshold
- Absence of spin dependence in the final state interaction of the d(pol) p --> 3He eta reaction
- Has a "" Signal in p+p Reactions been Observed Yet?
- Analysis framework for the J-PET scanner
- Measurement of the pn -> dK^+K^- total cross section close to threshold
Cited by in corpus (7)
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- Discrete symmetries tested at 10 precision using linear polarization of photons from positronium annihilations
- The J-PET detector -- a tool for precision studies of ortho-positronium decays
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
- Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
- Analysis procedure of the positronium lifetime spectra for the J-PET detector
- Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner