Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
arXiv:1911.12059
Abstract
Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph. The experiment was performed using the Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV
References in corpus (9)
- Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
- Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
- A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- Sampling FEE and Trigger-less DAQ for the J-PET Scanner
- Scatter fraction of the J-PET tomography scanner
- Overview of the software architecture and data flow for the J-PET tomography device
- Overview of the software architecture and data flow for the J-PET tomography device
- Commissioning of the J-PET detector for studies of decays of positronium atoms