most citedSimulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

105 citations · 194 across the 10 of their papers we have counts for

collaborators

10 papers

physics.ins-det2024★ 12 cited

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

L. Kaplon, J. Baran, N. Chug +31

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…

physics.med-ph2023

Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

Meysam Dadgar, Szymon Parzych, Jakub Baran +28

Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and…

physics.med-ph2023★ 3 cited

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

R. Y. Shopa, J. Baran, K. Klimaszewski +32

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (T…

physics.ins-det2021★ 105 cited

Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

Paweł Moskal, Paweł Kowalski, Roman Shopa +26

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scinti…

physics.ins-det2020

Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

N. G. Sharma, M. Silarski, J. Chhokar +32

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recen…

physics.med-ph2019★ 2 cited

Development of J-PEM for breast cancer detection and diagnosis using positronium imaging

Shivani, Elżbieta Luczyńska, Sylwia Heinze +1

The purpose of the presented investigations is to design, construct and establish the characteristic performance of the Jagiellonian Positron Emission Mammography(J-PEM), being des…

physics.ins-det2019★ 3 cited

Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

S. Sharma, J. Chhokar, C. Curceanu +36

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT…

physics.ins-det2019

Performance assessment of the 2 positronium imaging with the total-body PET scanners

P. Moskal, D. Kisielewska, Z. Bura +39

In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue,…

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

physics.ins-det2017★ 14 cited

Analysis procedure of the positronium lifetime spectra for the J-PET detector

K. Dulski, B. Zgardzinska, P. Bialas +30

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…