most citedEvaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

96 citations · 437 across the 15 of their papers we have counts for

collaborators

15 papers

physics.ins-det2020★ 17 cited

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

P. Moskal, T. Bednarski, Sz. Niedzwiecki +36

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a…

physics.ins-det2019★ 3 cited

Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

S. Sharma, J. Chhokar, C. Curceanu +36

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT…

physics.ins-det2019★ 1 cited

Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

N. Krawczyk, B. C. Hiesmayr, C. Curceanu +31

J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such…

physics.ins-det2018★ 14 cited

Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

K. Dulski, C. Curceanu, E. Czerwiński +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for s…

physics.ins-det2018★ 3 cited

A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

J. Raj, A. Gajos, C. Curceanu +31

The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an…

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

physics.ins-det2018★ 96 cited

Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

G. Korcyl, P. Białas, C. Curceanu +36

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no…

physics.ins-det2018★ 1 cited

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

A. Gajos, C. Curceanu, E. Czerwiński +29

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The…

physics.ins-det2016★ 90 cited

Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

J. Smyrski, D. Alfs, T. Bednarski +29

We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons esca…

physics.ins-det2016★ 71 cited

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D. Kamińska, A. Gajos, E. Czerwiński +26

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PE…

physics.ins-det2015★ 2 cited

Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

L. Raczynski, P. Moskal, P. Kowalski +24

Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast det…

physics.med-ph2015★ 12 cited

3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

Artur Słomski, Zbigniew Rudy, Tomasz Bednarski +23

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of m…

physics.ins-det2015★ 26 cited

Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

Łukasz Kapłon, Andrzej Kochanowski, Marcin Molenda +24

This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing pro…

physics.ins-det2013★ 5 cited

Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

J. Smyrski, P. Moskal, T. Bednarski +23

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this me…

physics.ins-det2013★ 41 cited

A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

M. Pałka, T. Bednarski, P. Białas +23

This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic…