219 citations · 454 across the 8 of their papers we have counts for
8 papers
Multiple scattering and accidental coincidences in the J-PET detector simulated using GATE package
P. Kowalski, P. Moskal, W. Wiślicki +28
Novel Positron Emission Tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device,…
Analysis framework for the J-PET scanner
W. Krzemień, A. Gajos, A. Gruntowski +28
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. I…
Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals
P. Moskal, N. G. Sharma, M. Silarski +28
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors…
A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
A. Wieczorek, P. Moskal, Sz. Niedźwiecki +30
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In thi…
A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
P. Moskal, N. Zoń, T. Bednarski +26
A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a li…
Test of a single module of the J-PET scanner based on plastic scintillators
P. Moskal, Sz. Niedźwiecki, T. Bednarski +27
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge…
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
L. Raczynski, P. Moskal, P. Kowalski +26
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibili…
Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators
L. Raczyński, P. Kowalski, T. Bednarski +22
Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random…