Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
arXiv:2107.12750 · doi:10.1016/j.media.2021.102199
Abstract
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back -photons. The optimisation of its parameters is studied using Monte Carlo simulations of a 1-mm spherical source, NEMA IEC and XCAT phantoms inside the ideal J-PET scanner. The combination of high-pass filters which included the TOF filtered back-projection (FBP), resulted in spatial resolution, 1.5 higher in the axial direction than for the conventional 3D FBP. For realistic -minute scans of NEMA IEC and XCAT, which require a trade-off between the noise and spatial resolution, the need for Gaussian TOF kernel components, coupled with median post-filtering, is demonstrated. The best sets of 3D filter parameters were obtained by the Nelder-Mead minimisation of the mean squared error between the resulting and reference images. The approach allows training the reconstruction algorithm for custom scans, using the IEC phantom, when the temporal resolution is below 50 ps. The image quality parameters, estimated for the best outcomes, were systematically better than for the non-TOF FBP.
References in corpus (9)
- Test of a single module of the J-PET scanner based on plastic scintillators
- J-PET: a new technology for the whole-body PET imaging
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
- Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
- Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
- Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
- Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
- Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
Cited by in corpus (5)
- Decoherence puzzle in measurements of photons originating from electron-positron annihilation
- Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
- Special features of the Weyl-Heisenberg Bell basis imply unusual entanglement structure of Bell-diagonal states
- J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
- TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix