Quantum Entanglement Degree, Mean Positronium Lifetime, and the / Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia -- Concept, Challenges, and Predictions
arXiv:2605.00021 · doi:10.5604/01.3001.0055.7461
Abstract
This manuscript introduces a novel method to assess tissue oxygen concentration via the quantum entanglement (QE) of photons originating from positronium which is produced within the patient's body during positron emission tomography. We also investigate the possibility of assessing hypoxia by simultaneously detecting positronium lifetime and the positronium decay rate ratio. We introduce two distinct quantum sensing approaches. Method 1 utilizes the correlation between oxygen concentration and ortho-positronium (o-Ps) decay rates, relying on the simultaneous measurement of the mean o-Ps lifetime () and the -to- annihilation rate ratio of o-Ps (). Method 2 introduces a novel hypothesis: that the degree of QE is sensitive to the relative contribution of annihilation mechanisms (pick-off vs. conversion), which in turn depends on oxygen concentration. We derive a formula for partial pressure of oxygen () as a function of and and estimate the measurement accuracy required for these parameters - and for the degree of QE - to sense in-vivo oxygen pressure in the range between hypoxic and physoxic conditions. Theoretical models and quantitative estimates for , and for the degree of QE ( ) as a function of are provided for water, isopropanol, cyclohexane, isooctane, and adipose tissue. In particular, applying the formulas derived under the working hypothesis that in pick-off process the photons are not entangled, we estimated that for , the degree of quantum entanglement is equal to 0.890 for adipose, 0.886 for isopropanol, 0.867 for water, 0.818 for cyclohexane, and 0.784 for isooctane.
arXiv commentBio-Algorithms and Med-Systems 22 (2026) 56, https://bamsjournal.com/article/557461/en
References in corpus (36)
- Test of a single module of the J-PET scanner based on plastic scintillators
- Positronium imaging with the novel multiphoton PET scanner
- Feasibility study of the positronium imaging with the J-PET tomograph
- J-PET: a new technology for the whole-body PET imaging
- Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
- Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators
- Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
- Positronium Physics and Biomedical Applications
- Photon quantum entanglement in the MeV regime and its application in PET imaging
- First test of correction of the orthopositronium decay rate
- Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system
- Witnessing Entanglement In Compton Scattering Processes Via Mutually Unbiased Bases
- Entanglement of annihilation photons
- Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
- Measurement of positron lifetime to probe the mixed molecular states of liquid water
- Genuine Multipartite Entanglement in the -Photon Decay of Positronium
- Electric field effect on positronium formation in liquids
- Three-party entanglement from positronium
- Human Tissues Investigation Using PALS Technique
- QED and Fundamental Symmetries in Positronium Decays
- Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
- Pickoff and spin-conversion quenchings of ortho-positronium in oxygen
- Discrete symmetries tested at 10 precision using linear polarization of photons from positronium annihilations
- Probing entanglement in Compton interactions
- Performance of three-photon PET imaging: Monte Carlo simulations
- Three Photon Entanglement from Ortho-Positronium Revisited
- Decoherence puzzle in measurements of photons originating from electron-positron annihilation
- Kinematic analysis of multiple Compton scattering in quantum-entangled two-photon systems
- Positronium Imaging: History, Current Status, and Future Perspectives
- Optimization of detector modules for measuring gamma-ray polarization in Positron Emission Tomography
- Ortho-positronium Lifetime For Soft-tissue Classification
- Measuring the Evolution of Entanglement in Compton Scattering
- Investigation of the spatial resolution of PET imaging system measuring polarization-correlated Compton events
- First positronium imaging using Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom
- First Positronium Lifetime Imaging using Mn and Co with a plastic-based PET scanner
- A reconciliation of the Pryce-Ward and Klein-Nishina statistics for semi-classical simulations of annihilation photons correlations