activity
20132015
most citedTest of a single module of the J-PET scanner based on plastic scintillators

219 citations · 403 across the 13 of their papers we have counts for

collaborators

13 papers

physics.med-ph2015★ 12 cited

3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

Artur Słomski, Zbigniew Rudy, Tomasz Bednarski +23

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of m…

physics.ins-det2015★ 26 cited

Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

Łukasz Kapłon, Andrzej Kochanowski, Marcin Molenda +24

This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing pro…

physics.ins-det2015★ 15 cited

A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

A. Wieczorek, P. Moskal, Sz. Niedźwiecki +30

For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In thi…

physics.ins-det2014★ 219 cited

Test of a single module of the J-PET scanner based on plastic scintillators

P. Moskal, Sz. Niedźwiecki, T. Bednarski +27

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge…

physics.ins-det2014★ 60 cited

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

L. Raczynski, P. Moskal, P. Kowalski +26

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibili…

physics.ins-det2014★ 4 cited

Database and data structure for the novel TOF-PET detector developed for J-PET project

E. Czerwiński, M. Zieliński, T. Bednarski +25

The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing.…

physics.comp-ph2014★ 1 cited

Computing support for advanced medical data analysis and imaging

W. Wiślicki, T. Bednarski, P. Białas +24

We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service archite…

physics.ins-det2013★ 6 cited

Calibration of photomultipliers gain used in the J-PET detector

T. Bednarski, E. Czerwiński, P. Moskal +27

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electr…

physics.ins-det2013★ 5 cited

Simulations of gamma quanta scattering in a single module of the J-PET detector

K. Szymański, P. Moskal, T. Bednarski +27

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed…

physics.ins-det2013★ 5 cited

Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

J. Smyrski, P. Moskal, T. Bednarski +23

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this me…

physics.ins-det2013★ 41 cited

A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

M. Pałka, T. Bednarski, P. Białas +23

This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic…

physics.ins-det2013★ 6 cited

J-PET analysis framework for the prototype TOF-PET detector

W. Krzemień, M. Silarski, K. Stola +25

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruc…

physics.ins-det2013★ 3 cited

A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

M. Silarski, E. Czerwiński, T. Bednarski +23

All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. Na or Ge, which are placed or rotate…