Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
arXiv:1709.00800 · doi:10.1103/PhysRevD.96.112011
Abstract
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil measurements that have been explored in liquid xenon.
arXiv comment10 pages, 10 figures, 2 tables
References in corpus (25)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Results from a search for dark matter in the complete LUX exposure
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- The Large Underground Xenon (LUX) Experiment
- Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- Two-Phase Emission Detector for Measuring Coherent Neutrino-Nucleus Scattering
- Tritium calibration of the LUX dark matter experiment
- Neutrino physics with multi-ton scale liquid xenon detectors
- Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- Enhancement of NEST Capabilities for Simulating Low-Energy Recoils in Liquid Xenon
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- The scintillation and ionization yield of liquid xenon for nuclear recoils
- Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
- Measurement of single electron emission in two-phase xenon
- Signal yields, energy resolution, and recombination fluctuations in liquid xenon
- Response of liquid xenon to Compton electrons down to 1.5 keV
- Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
- Performance and Fundamental Processes at Low Energy in a Two-Phase Liquid Xenon Dark Matter Detector
- Data Acquisition and Readout System for the LUX Dark Matter Experiment
- Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
- Measurement of light and charge yield of low-energy electronic recoils in liquid xenon
- Measurements of wavelength-dependent double photoelectron emission from single photons in VUV-sensitive photomultiplier tubes
Cited by in corpus (42)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Light Dark Matter Search with Ionization Signals in XENON1T
- Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Directly detecting sub-GeV dark matter with electrons from nuclear scattering
- On the relation between Migdal effect and dark matter-electron scattering in isolated atoms and semiconductors
- Search for Light Dark Matter-Electron Scatterings in the PandaX-II Experiment
- Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
- Electron Ionization via Dark Matter-Electron Scattering and the Migdal Effect
- New limits on dark photons from solar emission and keV scale dark matter
- Search for light dark matter with ionization signals in the PandaX-4T Experiment
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- Investigation of background electron emission in the LUX detector
- Solar Reflection of Dark Matter
- Inverse Primakoff Scattering as a Probe of Solar Axions at Liquid Xenon Direct Detection Experiments
- A search for new physics in low-energy electron recoils from the first LZ exposure
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Search for annual and diurnal rate modulations in the LUX experiment
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Direct Detection of Dark Matter -- APPEC Committee Report
- Extending light WIMP searches to single scintillation photons in LUX
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- Measurement of Charge and Light Yields for Xe L-Shell Electron Captures in Liquid Xenon
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Correlated Single- and Few-Electron Backgrounds Milliseconds after Interactions in Dual-Phase Liquid Xenon Time Projection Chambers
- First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
- Cosmogenic production of Ar in the context of the LUX-ZEPLIN experiment
- Prospects of charge signal analyses in liquid xenon TPCs with proportional scintillation in the liquid phase
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- Search for two neutrino double electron capture of Xe and Xe in the full exposure of the LUX detector
- Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon
- Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
- Feasibility of Liquid-phase Xenon Proportional Scintillation for Low-energy Physics
- Electron-ion recombination in composite interactions in liquid xenon
- Development of a Xe calibration source for nEXO
- A flexible test facility for liquid xenon detector development
- Observing the Migdal effect from nuclear recoils of neutral particles with liquid xenon and argon detectors