Feasibility of Liquid-phase Xenon Proportional Scintillation for Low-energy Physics
arXiv:2408.01646 · doi:10.1103/PhysRevD.111.012005
Abstract
Dual phase xenon time projection chambers (TPCs) detect both the scintillation photons and ionization electrons created by energy depositions within the liquid xenon (LXe) volume. The electrons are extracted from the interaction site through a gas gap, where they meet a high electric field where proportional scintillation occurs. This converts the electron signal into a light signal, and yields a high electron detection efficiency with a gain of tens of photoelectrons (PE) per electron. This technique of detecting both scintillation and ionization gives dual phase xenon TPCs the capability to distinguish between electronic and nuclear recoils, which is a key part of how these detectors are able to reach world-leading limits on Weakly Interacting Massive Particle (WIMP) dark matter. However, not all electrons can be extracted through the liquid-gas interface, and a constant millimeter-scale gas gap needs to be maintained, which may be a technological challenge if dual-phase xenon TPCs are to be scaled up for future dark matter searches. Furthermore, there is a background of single-electron peaks that follow a large ionization signal (S2) of unclear origin which may be due in part to the liquid-gas interface, and limits the sensitivity of these detectors towards low mass dark matter. In this paper, we demonstrate that a purely single-phase liquid xenon TPC which produces proportional scintillation directly in the liquid is still capable of discriminating between electronic and nuclear recoils, but that the background of single-electrons following an S2 is still likely unrelated to the liquid-gas interface.
arXiv comment14 pages, 27 figures, 4 page appendix
References in corpus (24)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Light Dark Matter Search with Ionization Signals in XENON1T
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
- Search for New Physics in Electronic Recoil Data from XENONnT
- Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
- Search for light dark matter with ionization signals in the PandaX-4T Experiment
- Investigation of background electron emission in the LUX detector
- Secondary Scintillation Yield in Pure Xenon
- Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
- Two distinct components of the delayed single electron background signals in liquid xenon emission detectors
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- -Decay Spectrum, Response Function and Statistical Model for Neutrino Mass Measurements with the KATRIN Experiment
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- Measurements of proportional scintillation and electron multiplication in liquid xenon using thin wires
- Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
- Correlated Single- and Few-Electron Backgrounds Milliseconds after Interactions in Dual-Phase Liquid Xenon Time Projection Chambers
- Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
- Low Energy Electronic Recoils and Single Electron Detection with a Liquid Xenon Proportional Scintillation Counter
- Proposal of a Geiger-type Single-Phase Liquid Xenon Time Projection Chamber as Potential Detector Technique for Dark Matter Direct Search
- Performance of a Radial Time Projection Chamber with Electroluminescence in Liquid Xenon
- First observation of liquid xenon electroluminescence with a Microstrip Plate