Abstract
We characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.
arXiv comment16 pages, 7 figures, 1 table
References in corpus (26)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Results from a search for dark matter in the complete LUX exposure
- Direct Detection of Sub-GeV Dark Matter
- A search for light dark matter in XENON10 data
- Light Dark Matter Search with Ionization Signals in XENON1T
- Excess Electronic Recoil Events in XENON1T
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset
- Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
- Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
- A low-mass dark matter search using ionization signals in XENON100
- Results of Dark Matter Search using the Full PandaX-II Exposure
- Supernova neutrino physics with xenon dark matter detectors: A timely perspective
- Observation and applications of single-electron charge signals in the XENON100 experiment
- Investigation of background electron emission in the LUX detector
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- Two distinct components of the delayed single electron background signals in liquid xenon emission detectors
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- First ground-level laboratory test of the two-phase xenon emission detector RED-100
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- Calibration of a two-phase xenon time projection chamber with a Ar source
- LBECA: A Low Background Electron Counting Apparatus for Sub-GeV Dark Matter Detection
- Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber
- The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
- Development and Performance of a Sealed Liquid Xenon Time Projection Chamber
Cited by in corpus (13)
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
- Searches for light dark matter using condensed matter systems
- Low Energy Electronic Recoils and Single Electron Detection with a Liquid Xenon Proportional Scintillation Counter
- Detecting Low-Energy Interactions and the Effects of Energy Accumulation in Materials
- Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches
- Feasibility Study to use Neutron Capture for an Ultra-low Energy Nuclear-recoil Calibration in Liquid Xenon
- Production and suppression of delayed light in NaI
- Feasibility of Liquid-phase Xenon Proportional Scintillation for Low-energy Physics
- Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
- Unraveling the puzzle of slow components in gaseous argon of two-phase detectors for dark matter searches using Thick Gas Electron Multiplier
- Electron transfer efficiency in liquid xenon across THGEM holes
- A measurement of the mean electronic excitation energy of liquid xenon