A measurement of the mean electronic excitation energy of liquid xenon
arXiv:2109.07151 · doi:10.1140/epjc/s10052-021-09834-x
Abstract
Detectors using liquid xenon as target are widely deployed in rare event searches. Conclusions on the interacting particle rely on a precise reconstruction of the deposited energy which requires calibrations of the energy scale of the detector by means of radioactive sources. However, a microscopic calibration, i.e. the translation from the number of excitation quanta into deposited energy, also necessitates good knowledge of the energy required to produce single scintillation photons or ionisation electrons in liquid xenon. The sum of these excitation quanta is directly proportional to the deposited energy in the target. The proportionality constant is the mean excitation energy and is commonly known as -value. Here we present a measurement of the -value with electronic recoil interactions in a small dual-phase xenon time projection chamber with a hybrid (photomultiplier tube and silicon photomultipliers) photosensor configuration. Our result is based on calibrations at with internal Ar and Kr sources and single electron events. We obtain a value of , with negligible statistical uncertainty, which is lower than previously measured at these energies. If further confirmed, our result will be relevant for modelling the absolute response of liquid xenon detectors to particle interactions.
12 pages, 4 figures, 2 tables. v2: external crosstalk considered, NEST comparison and references added, typos corrected
References in corpus (13)
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- Excess Electronic Recoil Events in XENON1T
- First observation of two-neutrino double electron capture in Xe with XENON1T
- Measurement of single electron emission in two-phase xenon
- Characterization of the Hamamatsu VUV4 MPPCs for nEXO
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Performance and Fundamental Processes at Low Energy in a Two-Phase Liquid Xenon Dark Matter Detector
- Correlated Single- and Few-Electron Backgrounds Milliseconds after Interactions in Dual-Phase Liquid Xenon Time Projection Chambers
- The first dual-phase xenon TPC equipped with silicon photomultipliers and characterisation with Ar