Abstract
We present the precision calibration of 35 Hamamatsu R11410-22 photomultiplier tubes (PMTs) with xenon scintillation light centred near 175 nm. This particular PMT variant was developed specifically for the LUX-ZEPLIN (LZ) dark matter experiment. A room-temperature xenon scintillation cell coupled to a vacuum cryostat was used to study the full-face PMT response at both room and low temperature $\textrm{($\sim^\circ$C)}$, in particular to determine the quantum efficiency (QE) and double photoelectron emission (DPE) probability in LZ operating conditions. For our sample with an average QE of $\textrm{(32.4$\pm at room temperature, we find a relative improvement of $\textrm{(17.9$\pm upon cooling (where uncertainty values refer to the sample standard deviation). The mean DPE probability in response to single vacuum ultraviolet (VUV) photons is $\textrm{(22.6$\pm at low temperature; the DPE increase relative to room temperature, measured here for the first time, was $\textrm{(12.2$\pm. Evidence of a small triple photoelectron emission probability $\textrm{($\sim has also been observed. Useful correlations are established between these parameters and the QE as measured by the manufacturer. The single VUV photon response is also measured for one ETEL D730/9829QB, a PMT with a more standard bialkali photocathode used in the ZEPLIN-III experiment, for which we obtained a cold DPE fraction of $\textrm{(9.1$\pm. Hence, we confirm that this effect is not restricted to the low-temperature bialkali photocathode technology employed by Hamamatsu. This highlights the importance of considering this phenomenon in the interpretation of data from liquid xenon scintillation and electroluminescence detectors, and from many other optical measurements in this wavelength region.
arXiv comment13 pages, 16 figures
References in corpus (16)
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- The Large Underground Xenon (LUX) Experiment
- Liquid noble gas detectors for low energy particle physics
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic Xenon Environments
- Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector
- Measurement of the absolute Quantum Efficiency of Hamamatsu model R11410-10 photomultiplier tubes at low temperatures down to liquid xenon boiling point
- Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs
- Performance of Photosensors in the PandaX-I Experiment
- ZE3RA: The ZEPLIN-III Reduction and Analysis Package
- Calibration of Photomultiplier Arrays
- Measurements of the position-dependent photo-detection sensitivity of the Hamamatsu R11410 and R8520 photomultiplier tubes
Cited by in corpus (25)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
- The LUX-ZEPLIN (LZ) Experiment
- Dark Matter Search Results from 4.2 Tonne-Years of Exposure of the LUX-ZEPLIN (LZ) Experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- A search for new physics in low-energy electron recoils from the first LZ exposure
- Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Extending light WIMP searches to single scintillation photons in LUX
- Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers
- Improved quality tests of R11410-21 photomultiplier tubes for the XENONnT experiment
- The throughput calibration of the VERITAS telescopes
- Investigating the XENON1T Low-Energy Electronic Recoil Excess Using NEST
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Reactor neutrino liquid xenon coherent elastic scattering experiment
- Direct dark matter searches with the full data set of XMASS-I
- Prospects of charge signal analyses in liquid xenon TPCs with proportional scintillation in the liquid phase
- A machine learning-based methodology for pulse classification in dual-phase xenon time projection chambers
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- A Novel Low-Background Photomultiplier Tube Developed for Xenon Based Detectors
- The Fast Stochastic Matching Pursuit for Neutrino and Dark Matter Experiments
- Design Challenges for a Future Liquid Xenon Observatory
- A measurement of the mean electronic excitation energy of liquid xenon
- Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne\times Year Exposure from the LZ Experiment