Investigating the XENON1T Low-Energy Electronic Recoil Excess Using NEST
arXiv:2007.00528 · doi:10.1103/PhysRevD.103.012002
Abstract
The search for dark matter, the missing mass of the Universe, is one of the most active fields of study within particle physics. The XENON1T experiment recently observed a 3.5 excess potentially consistent with dark matter, or with solar axions. Here, we will use the Noble Element Simulation Technique (NEST) software to simulate the XENON1T detector, reproducing the excess. We utilize different detector efficiency and energy reconstruction models, but they primarily impact sub-keV energies and cannot explain the XENON1T excess. However, using NEST, we can reproduce their excess in multiple, unique ways, most easily via the addition of 3111 decays. Furthermore, this results in new, modified background models, reducing the significance of the excess to at least using non-Profile Likelihood Ratio (PLR) methods. This is independent confirmation that the excess is a real effect, but potentially explicable by known physics. Many cross-checks of our hypothesis are presented.
arXiv commentpublished version
References in corpus (43)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Planck 2018 results. I. Overview and the cosmological legacy of Planck
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Results from a search for dark matter in the complete LUX exposure
- First Dark Matter Search Results from the XENON1T Experiment
- Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
- Light Dark Matter Search with Ionization Signals in XENON1T
- Excess Electronic Recoil Events in XENON1T
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- The XENON1T Dark Matter Experiment
- NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- First Axion Results from the XENON100 Experiment
- First observation of two-neutrino double electron capture in Xe with XENON1T
- A low-mass dark matter search using ionization signals in XENON100
- Tritium calibration of the LUX dark matter experiment
- Enhancement of NEST Capabilities for Simulating Low-Energy Recoils in Liquid Xenon
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- A Global Analysis of Light and Charge Yields in Liquid Xenon
- Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons
- Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
- XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
- Constraining Dark Matter Models with a Light Mediator from PandaX-II Experiment
- Signal yields, energy resolution, and recombination fluctuations in liquid xenon
- Search for annual and diurnal rate modulations in the LUX experiment
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Response of photomultiplier tubes to xenon scintillation light
- Response of liquid xenon to Compton electrons down to 1.5 keV
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
- A Rn-220 source for the calibration of low-background experiments
- Measurement of light and charge yield of low-energy electronic recoils in liquid xenon
- Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
- XENON1T Excess: Some Possible Backgrounds
- Anomalous Gauge Bosons as Light Dark Matter in String Theory
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- A model independent safeguard for unbinned Likelihood
- Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber
- Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
Cited by in corpus (19)
- Search for New Physics in Electronic Recoil Data from XENONnT
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Search for Light Dark Matter-Electron Scatterings in the PandaX-II Experiment
- Exploring New Physics with O(keV) Electron Recoils in Direct Detection Experiments
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Prospects of Migdal Effect in the Explanation of XENON1T Electron Recoil Excess
- Global fits of axion-like particles to XENON1T and astrophysical data
- Projected sensitivities of the LUX-ZEPLIN (LZ) experiment to new physics via low-energy electron recoils
- What if ALP dark matter for the XENON1T excess is the inflaton
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Constraints on electron-scattering interpretation of XENON1T excess
- XENON1T Excess: Some Possible Backgrounds
- Cosmogenic production of Ar in the context of the LUX-ZEPLIN experiment
- GeV Scale Inelastic Dark Matter with Dark Photon Mediator via Direct Detection and Cosmological/Laboratory Constraints
- Terrestrial Probes of Electromagnetically Interacting Dark Radiation
- Explorations of pseudo-Dirac dark matter having keV splittings and interacting via transition electric and magnetic dipole moments
- Dark Fluxes from Accreting Black Holes and Direct Detections
- Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon
- Solar wind bremsstrahlung off DM in our solar system