Measurement of light and charge yield of low-energy electronic recoils in liquid xenon
arXiv:1611.10322 · doi:10.1103/PhysRevD.96.103007
Abstract
The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field dependence at recoil energies less than 10 keV. In this paper we present results of such measurements using a specialized detector. Recoil energies are determined via the Compton coincidence technique at four drift fields relevant for liquid xenon dark matter detectors: 0.19, 0.48, 1.02, and 2.32 kV/cm. Mean recoil energies down to 1 keV were measured with unprecedented precision. We find that the charge and light yield are anti-correlated above 3 keV, and that the field dependence becomes negligible below 6 keV. However, below 3 keV we find a charge yield significantly higher than expectation and a reconstructed energy deviating from linearity.
17 pages, 9 figures
References in corpus (6)
- Physics reach of the XENON1T dark matter experiment
- Tritium calibration of the LUX dark matter experiment
- Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
- Search for Event Rate Modulation in XENON100 Electronic Recoil Data
- Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
- Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm
Cited by in corpus (20)
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Directly detecting sub-GeV dark matter with electrons from nuclear scattering
- Directly Detecting MeV-scale Dark Matter via Solar Reflection
- Results of Dark Matter Search using the Full PandaX-II Exposure
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- Investigation of background electron emission in the LUX detector
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Search for annual and diurnal rate modulations in the LUX experiment
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
- Investigating the XENON1T Low-Energy Electronic Recoil Excess Using NEST
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- The first dual-phase xenon TPC equipped with silicon photomultipliers and characterisation with Ar
- Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
- Simultaneous measurement of the light and charge response of liquid xenon to low-energy nuclear recoils at multiple electric fields
- Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon
- Characterization of photomultiplier tubes with a realistic model through GPU-boosted simulation
- Search for inelastic WIMP-iodine scattering with COSINE-100
- Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne\times Year Exposure from the LZ Experiment