Signal yields, energy resolution, and recombination fluctuations in liquid xenon
arXiv:1610.02076 · doi:10.1103/PhysRevD.95.012008
Abstract
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.
11 pages, 12 figures, 3 tables
References in corpus (3)
Cited by in corpus (16)
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- First observation of two-neutrino double electron capture in Xe with XENON1T
- Confirming as a solution for with neutrinos
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Kr calibration of the 2013 LUX dark matter search
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Signal Response Model in PandaX-4T
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Neutrino Backgrounds in Future Liquid Noble Element Dark Matter Direct Detection Experiments
- Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
- Exploring light dark matter with the Migdal effect in hydrogen-doped liquid xenon
- Isospin-violating dark matter at liquid noble detectors: new constraints, future projections, and an exploration of target complementarity
- Light yield and field dependence measurement in PandaX-II dual-phase xenon detector