A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers
arXiv:0912.2337 · doi:10.1088/1748-0221/5/05/P05006
Abstract
We report the testing of a charcoal-based Kr-83m source for use in calibrating a low background two-phase liquid xenon detector. Kr-83m atoms produced through the decay of Rb-83 are introduced into a xenon detector by flowing xenon gas past the Rb-83 source. 9.4 keV and 32.1 keV transitions from decaying 83Krm nuclei are detected through liquid xenon scintillation and ionization. The characteristics of the Kr-83m source are analyzed and shown to be appropriate for a low background liquid xenon detector. Introduction of Kr-83m allows for quick, periodic calibration of low background noble liquid detectors at low energy.
Updated to version submitted to JINST
References in corpus (6)
- Five-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Cosmological Interpretation
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- Calibration of a Liquid Xenon Detector with Kr-83m
- Calibration of liquid argon and neon detectors with
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
Cited by in corpus (15)
- Results from a search for dark matter in the complete LUX exposure
- Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
- Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- After LUX: The LZ Program
- Signal yields, energy resolution, and recombination fluctuations in liquid xenon
- Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
- Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
- Kr calibration of the 2013 LUX dark matter search
- A Rn-220 source for the calibration of low-background experiments
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Application and performance of an ML-EM algorithm in NEXT
- A novel Kr tracer method for characterizing xenon gas and cryogenic distillation systems
- Analysis of Kr Prompt Scintillation Signals in the PIXeY Detector
- Development of a Kr source for the calibration of the CENNS-10 Liquid Argon Detector