Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
arXiv:1611.03585 · doi:10.1103/PhysRevD.95.072008
Abstract
A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220/Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.
References in corpus (25)
- Dark Matter Results from 225 Live Days of XENON100 Data
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Physics reach of the XENON1T dark matter experiment
- Search for Majorana neutrinos with the first two years of EXO-200 data
- Dark matter direct-detection experiments
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- DARWIN: towards the ultimate dark matter detector
- The XENON100 Dark Matter Experiment
- First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
- Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
- Results from the first use of low radioactivity argon in a dark matter search
- First Axion Results from the XENON100 Experiment
- Tritium calibration of the LUX dark matter experiment
- Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
- Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
- Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200
- Search for Event Rate Modulation in XENON100 Electronic Recoil Data
- Characterization of Silicon Photomultipliers for nEXO
- Radioactivity Backgrounds in ZEPLIN-III
- Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
- Investigation of rare nuclear decays with BaF crystal scintillator contaminated by radium
- A Rn-220 source for the calibration of low-background experiments
- Search for neutrinoless double beta decay
- A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers
- Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project
Cited by in corpus (28)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- First Dark Matter Search Results from the XENON1T Experiment
- Light Dark Matter Search with Ionization Signals in XENON1T
- Dark matter direct-detection experiments
- Search for New Physics in Electronic Recoil Data from XENONnT
- The XENON1T Dark Matter Experiment
- Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Investigation of background electron emission in the LUX detector
- XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
- PandaX-xT: a Multi-ten-tonne Liquid Xenon Observatory at the China Jinping Underground Laboratory
- Online Rn removal by cryogenic distillation in the XENON100 experiment
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- Direct Detection of Dark Matter -- APPEC Committee Report
- The XENON1T Data Acquisition System
- Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
- Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
- Detector signal characterization with a Bayesian network in XENONnT
- Proposal of a Geiger-type Single-Phase Liquid Xenon Time Projection Chamber as Potential Detector Technique for Dark Matter Direct Search
- Characterization of a Rn source for low-energy electronic recoil calibration of the XENONnT detector
- Prospects of detecting the reactor -Ar coherent elastic scattering with a low threshold dual-phase argon time projection chamber at Taishan
- Half-life measurements of Po with thorium-loaded liquid scintillator
- Neutron inelastic scattering measurements on Xe at = 0.7 to 100 MeV
- Development of a Xe calibration source for nEXO
- The half-life of Po
- Flow and thermal modelling of the argon volume in the DarkSide-20k TPC