Development of a Xe calibration source for nEXO
arXiv:2201.04681 · doi:10.1088/1748-0221/17/07/P07028
Abstract
We study a possible calibration technique for the nEXO experiment using a Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay () that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of Xe and its small -value compared to that of Xe would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
arXiv comment24 pages, 16 figures
References in corpus (20)
- NEXO: Neutrinoless double beta decay search beyond year half-life sensitivity
- Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon
- Tritium calibration of the LUX dark matter experiment
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- nEXO Pre-Conceptual Design Report
- Calibration of a Liquid Xenon Detector with Kr-83m
- Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
- Kr calibration of the 2013 LUX dark matter search
- Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
- Characterization of an Ionization Readout Tile for nEXO
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
- A Rn-220 source for the calibration of low-background experiments
- Measurement of Charge and Light Yields for Xe L-Shell Electron Captures in Liquid Xenon
- Simulation of charge readout with segmented tiles in nEXO
- GEANT4 models of HPGe detectors for radioassay
- The EXO-200 detector, part II: Auxiliary Systems
- An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout