A flexible test facility for liquid xenon detector development
arXiv:2508.05853 · doi:10.1088/1748-0221/20/11/P11005
Abstract
As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. We describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.
18 pages, 9 figures; version accepted by JINST
References in corpus (20)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
- Fog on the horizon: a new definition of the neutrino floor for direct dark matter searches
- NEXO: Neutrinoless double beta decay search beyond year half-life sensitivity
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
- Dark Matter Search Results from 1.54 TonneYear Exposure of PandaX-4T
- PandaX-xT: a Multi-ten-tonne Liquid Xenon Observatory at the China Jinping Underground Laboratory
- Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
- Characterization of an Ionization Readout Tile for nEXO
- A Rn-220 source for the calibration of low-background experiments
- A magnetically-driven piston pump for ultra-clean applications
- Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
- Simulation of charge readout with segmented tiles in nEXO
- Magnetically-coupled piston pump for high-purity gas applications
- The XeBRA platform for liquid xenon time projection chamber development
- Characterization of a Rn source for low-energy electronic recoil calibration of the XENONnT detector
- Development of a Xe calibration source for nEXO