Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200
arXiv:1506.00317 · doi:10.1103/PhysRevC.92.045504
Abstract
Alpha decays in the EXO-200 detector are used to measure the fraction of charged and daughters created from alpha and beta decays, respectively. alpha decays in liquid xenon (LXe) are found to produce ions of the time, while the remainder of the atoms are neutral. The fraction of from beta decays in LXe is found to be , inferred from the relative rates of and alpha decays in the LXe. The average velocity of ions is observed to decrease for longer drift times. Initially the ions have a mobility of , and at long drift times the mobility is . Time constants associated with the change in mobility during drift of the ions are found to be proportional to the electron lifetime in the LXe.
References in corpus (4)
- Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- Investigation of radioactivity-induced backgrounds in EXO-200
- Spectroscopy of Ba and Ba deposits in solid xenon for barium tagging in nEXO
Cited by in corpus (31)
- Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
- NEXO: Neutrinoless double beta decay search beyond year half-life sensitivity
- Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
- Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
- Projected sensitivity of the LUX-ZEPLIN experiment to the decay of Xe
- Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
- Rn emanation measurements for the XENON1T experiment
- Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
- A Rn-220 source for the calibration of low-background experiments
- Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
- Solar neutrino detection in liquid xenon detectors via charged-current scattering to excited states
- Mobility and Clustering of Barium Ions and Dications in High Pressure Xenon Gas
- Design of a Multiple-Reflection Time-of-Flight Mass-Spectrometer for Barium-tagging
- Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
- Detection prospects for the second-order weak decays of Xe in multi-tonne xenon time projection chambers
- Search for nucleon decays with EXO-200
- Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector
- Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
- Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory
- An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
- On concentration of Ar in the Earth's atmosphere
- Towards a background-free neutrinoless double beta decay experiment based on a fluorescent bicolor sensor
- Krypton and radon background in the PandaX-I dark matter experiment
- Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
- Radon background in liquid xenon detectors
- Measurement of the ion fraction and mobility of Po produced in Rn decays in liquid argon
- Ion manipulation from liquid Xe to vacuum: Ba-tagging for a nEXO upgrade and future experiments
- Barium Chemosensors with Dry-Phase Fluorescence for Neutrinoless Double Beta Decay
- Canadian Contributions to the Search for Neutrinoless Double Beta Decay
- High Pressure Gas Xenon TPCs for Double Beta Decay Searches