Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
arXiv:0909.1063 · doi:10.1103/PhysRevC.81.025808
Abstract
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric field in LXe, finding no significant field dependence.
10 pages, 15 figures On version v4 we describe in more detail the trigger setup and have edited several figure to help the reader understand them
References in corpus (6)
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
- A Model of Nuclear Recoil Scintillation Efficiency in Noble Liquids
- Scintillation of liquid neon from electronic and nuclear recoils
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
Cited by in corpus (93)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
- Dark Matter Results from 100 Live Days of XENON100 Data
- A search for light dark matter in XENON10 data
- Review of asymmetric dark matter
- First Dark Matter Results from the XENON100 Experiment
- DARWIN: towards the ultimate dark matter detector
- The XENON100 Dark Matter Experiment
- Migdal Effect in Dark Matter Direct Detection Experiments
- Liquid noble gas detectors for low energy particle physics
- NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon
- Dark Matter Direct Detection with Non-Maxwellian Velocity Structure
- CoGeNT Interpretations
- The Astrophysical Uncertainties Of Dark Matter Direct Detection Experiments
- Integrating Out Astrophysical Uncertainties
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- Implications of CoGeNT and DAMA for Light WIMP Dark Matter
- A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
- A light scalar WIMP through the Higgs portal and CoGeNT
- Likelihood Approach to the First Dark Matter Results from XENON100
- Exothermic Dark Matter
- Results of Dark Matter Search using the Full PandaX-II Exposure
- XENON10/100 dark matter constraints in comparison with CoGeNT and DAMA: examining the Leff dependence
- Dark Moments and the DAMA-CoGeNT Puzzle
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- Can neutralinos in the MSSM and NMSSM scenarios still be light?
- Enhancement of NEST Capabilities for Simulating Low-Energy Recoils in Liquid Xenon
- Quenching and Channeling of Nuclear Recoils in NaI[Tl]: Implications for Dark Matter Searches
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- A Concept for A Dark Matter Detector Using Liquid Helium-4
- A Global Analysis of Light and Charge Yields in Liquid Xenon
- Response of the XENON100 Dark Matter Detector to Nuclear Recoils
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- Can CoGeNT and DAMA Modulations Be Due to Dark Matter?
- Relic neutralinos and the two dark matter candidate events of the CDMS II experiment
- Interplay between scintillation and ionization in liquid xenon Dark Matter searches
- Light Neutralinos with Large Scattering Cross Sections in the Minimal Supersymmetric Standard Model
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- WIMP astronomy and particle physics with liquid-noble and cryogenic direct-detection experiments
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- Implications of CoGeNT's New Results For Dark Matter
- Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
- Light Dark Matter Anomalies After LUX
- Measurement of scintillation efficiency for nuclear recoils in liquid argon
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Limits on inelastic dark matter from ZEPLIN-III
- Light mixed sneutrinos as thermal dark matter
- Introduction to dark matter experiments
- Light Dark Matter, Light Higgs and the Electroweak Phase Transition
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Atomic limits in the search for galactic dark matter
- A coherent understanding of low-energy nuclear recoils in liquid xenon
- Response of liquid xenon to Compton electrons down to 1.5 keV
- Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
- Nuclear Fusion Inside Dark Matter
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- A Simple Explanation for DAMA with Moderate Channeling
- Scintillation of Liquid Helium for Low-Energy Nuclear Recoils
- Search for inelastic WIMP nucleus scattering on Xe in data from the XMASS-I experiment
- Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
- Using Effective Operators to Understand CoGeNT and CDMS-Silicon
- A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Dark Matter Direct Detection of Classical WIMPs
- Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon
- Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
- Measurement of the ionization yield of nuclear recoils in liquid argon at 80 and 233 keV
- Simultaneous measurement of the light and charge response of liquid xenon to low-energy nuclear recoils at multiple electric fields
- Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm
- Neutrino Backgrounds in Future Liquid Noble Element Dark Matter Direct Detection Experiments
- Revisiting XENON100's Constraints (and Signals?) For Low-Mass Dark Matter
- Study of nuclear recoils in liquid argon with monoenergetic neutrons
- Low-energy Calibration of XENON1T with an Internal Ar Source
- Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap
- New libraries for simulating neutron scattering in dark matter detector calibrations
- Dual-Phase Liquid Xenon Detectors for Dark Matter Searches
- A Spin-Dependent Interpretation for Possible Signals of Light Dark Matter
- Importance of upgraded energy reconstruction for direct dark matter searches with liquid xenon detectors
- Design and demonstration of a quasi-monoenergetic neutron source
- The XENON100 exclusion limit without considering Leff as a nuisance parameter
- Gif Lectures on direct detection of Dark Matter
- A New Method for Analysing Dark Matter Direct Detection Data
- Interactions of exotic particles with ordinary matter
- Feasibility Study to use Neutron Capture for an Ultra-low Energy Nuclear-recoil Calibration in Liquid Xenon
- Electron recombination in low-energy nuclear recoils tracks in liquid argon
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- A Comprehensive Study of Low-Energy Response for Xenon-Based Dark Matter Experiments
- Constraints on Inelastic Dark Matter Signal using ZEPLIN-II Results
- Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches
- Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments
- A Novel Source of Tagged Low-Energy Nuclear Recoils
- Searching for low-mass dark matter via Migdal effect in COSINE-100
- A low-mass dark matter project, ALETHEIA: A Liquid hElium Time projection cHambEr In dArk matter