The scintillation and ionization yield of liquid xenon for nuclear recoils
arXiv:0807.0459 · doi:10.1016/j.nima.2008.12.197
Abstract
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
arXiv comment8 pages, 9 figures. To be published in Nucl. Instrum. Methods A
References in corpus (16)
- Supersymmetric Dark Matter
- The Cosmological Parameters 2006
- Big-Bang nucleosynthesis (Particle Data Group mini-review)
- A direct empirical proof of the existence of dark matter
- First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
- Muon-Induced Background Study for Underground Laboratories
- Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
- Measuring and Understanding the Universe
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Discovery of a Ringlike Dark Matter Structure in the Core of the Galaxy Cluster Cl 0024+17
- Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
- Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
- Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils
- A survey of energy loss calculations for heavy ions between 1 and 100 keV
- Dark Matter Searches
- 3D Position Sensitive XeTPC for Dark Matter Search
Cited by in corpus (53)
- A search for light dark matter in XENON10 data
- First Dark Matter Results from the XENON100 Experiment
- Compatibility of DAMA/LIBRA dark matter detection with other searches
- Liquid noble gas detectors for low energy particle physics
- NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon
- Dark Matter Direct Detection with Non-Maxwellian Velocity Structure
- Semi-empirical calculation of quenching factors for ions in scintillators
- The Astrophysical Uncertainties Of Dark Matter Direct Detection Experiments
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Integrating Out Astrophysical Uncertainties
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Spin-independent elastic WIMP scattering and the DAMA annual modulation signal
- Global interpretation of direct Dark Matter searches after CDMS-II results
- Design and Performance of the XENON10 Dark Matter Experiment
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- Exothermic Dark Matter
- Constraints on inelastic dark matter from XENON10
- XENON10/100 dark matter constraints in comparison with CoGeNT and DAMA: examining the Leff dependence
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
- A Global Analysis of Light and Charge Yields in Liquid Xenon
- Response of the XENON100 Dark Matter Detector to Nuclear Recoils
- Dark matter scattering on electrons: Accurate calculations of atomic excitations and implications for the DAMA signal
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- Interplay between scintillation and ionization in liquid xenon Dark Matter searches
- Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
- Measurement of scintillation efficiency for nuclear recoils in liquid argon
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- A coherent understanding of low-energy nuclear recoils in liquid xenon
- Detection of reactor antineutrino coherent scattering off nuclei with a two-phase noble gas detector
- Improved Constraints on Inelastic Dark Matter
- Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
- Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
- Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
- A Simple Explanation for DAMA with Moderate Channeling
- Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
- Making sense of the local Galactic escape speed estimates in direct dark matter searches
- A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
- Ionization and scintillation of nuclear recoils in gaseous xenon
- Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
- Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm
- Simultaneous measurement of the light and charge response of liquid xenon to low-energy nuclear recoils at multiple electric fields
- Design and demonstration of a quasi-monoenergetic neutron source
- Feasibility Study to use Neutron Capture for an Ultra-low Energy Nuclear-recoil Calibration in Liquid Xenon
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- A Comprehensive Study of Low-Energy Response for Xenon-Based Dark Matter Experiments
- Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches
- A Novel Source of Tagged Low-Energy Nuclear Recoils
- Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments
- Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
- GEM-based detectors for direct detection of low-mass WIMP, solar axions and narrow resonances (quarks)