Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches
arXiv:2207.08326 · doi:10.1103/PhysRevD.106.052013
Abstract
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We report the xenon recoil responses and their electric field-dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2-2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.
arXiv comment11 pages, 8 figures, minor additions to text describing scintillator BDs and pulse shape discrimination, minor additions to text describing model fit procedure, Figure 2 modified to show full dataset from single drift field setting
References in corpus (32)
- Supersymmetric Dark Matter
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Results from 225 Live Days of XENON100 Data
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- Inelastic Dark Matter
- The Effective Field Theory of Dark Matter Direct Detection
- A search for light dark matter in XENON10 data
- Light Dark Matter Search with Ionization Signals in XENON1T
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- Direct Detection of WIMP Dark Matter: Concepts and Status
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- Non-relativistic effective theory of dark matter direct detection
- NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Toward (Finally!) Ruling Out Z and Higgs Mediated Dark Matter Models
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- Tritium calibration of the LUX dark matter experiment
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
- PandaX-II Constraints on Spin-Dependent WIMP-Nucleon Effective Interactions
- A Global Analysis of Light and Charge Yields in Liquid Xenon
- Response of the XENON100 Dark Matter Detector to Nuclear Recoils
- The scintillation and ionization yield of liquid xenon for nuclear recoils
- Investigation of background electron emission in the LUX detector
- Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
- Electron extraction efficiency study for dual-phase xenon dark matter experiments
- LUXSim: A Component-Centric Approach to Low-Background Simulations
- Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
- An Effective Field Theory Analysis of the First LUX Dark Matter Search