Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
arXiv:2102.06998 · doi:10.1103/PhysRevD.104.062005
Abstract
We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to 180 keV, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis techniques to account for higher-energy backgrounds was required. With a 3.14 kgday exposure using data collected between 2014 and 2016, we set 90\% C.L. exclusion limits on non-relativistic EFT WIMP couplings to neutrons and protons, providing the most stringent constraints on a significant fraction of the possible EFT WIMP interactions. Additionally, we report world-leading exclusion limits on inelastic EFT WIMP-nucleon recoils.
19 Pages, 10 Figures, 4 Table
References in corpus (21)
- A direct empirical proof of the existence of dark matter
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Candidates from Particle Physics and Methods of Detection
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- The Large Underground Xenon (LUX) Experiment
- Non-relativistic effective theory of dark matter direct detection
- Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- A Model Independent Approach to Inelastic Dark Matter Scattering
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- Investigation of background electron emission in the LUX detector
- Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
- Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Kr calibration of the 2013 LUX dark matter search
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- 3D Modeling of Electric Fields in the LUX Detector
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Dark Matter Searches with LUX
- Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
- An Effective Field Theory Analysis of the First LUX Dark Matter Search
Cited by in corpus (11)
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- First Constraints on WIMP-Nucleon Effective Field Theory Couplings in an Extended Energy Region From LUX-ZEPLIN
- Dark Matter from Monogem
- Results on photon-mediated dark matter-nucleus interactions from the PICO-60 CF bubble chamber
- Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
- The Design, Implementation, and Performance of the LZ Calibration Systems
- Effective field theory and inelastic dark matter results from XENON1T
- Uncertainties on the EFT coupling limits for direct dark matter detection experiments stemming from uncertainties of target properties
- Detection and Calibration of Low-Energy Nuclear Recoils for Dark Matter and Neutrino Scattering Experiments
- Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches