Position Reconstruction in LUX
arXiv:1710.02752 · doi:10.1088/1748-0221/13/02/P02001
Abstract
The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including Kr (releasing a total energy of 41.5 keV) and H ( with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an position uncertainty of = 0.82 cm for events of only 200 electroluminescence photons and = 0.17 cm for 4,000 electroluminescence photons. Such signals are associated with electron recoils of energies 0.25 keV and 10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface has a horizontal uncertainty of 2.13 cm.
arXiv comment30 pages, 17 figures
References in corpus (26)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
- The Large Underground Xenon (LUX) Experiment
- First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
- Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
- Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
- First Searches for Axions and Axion-Like Particles with the LUX Experiment
- Tritium calibration of the LUX dark matter experiment
- Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
- Calibration of a Liquid Xenon Detector with Kr-83m
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- Measurement of single electron emission in two-phase xenon
- ANTS2 package: simulation and experimental data processing for Anger camera type detectors
- Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
- An Ultra-Low Background PMT for Liquid Xenon Detectors
- Reflectance of Polytetrafluoroethylene (PTFE) for Xenon Scintillation Light
- LUXSim: A Component-Centric Approach to Low-Background Simulations
- Kr calibration of the 2013 LUX dark matter search
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- Anisotropic diffusion of electrons in liquid xenon with application to improving the sensitivity of direct dark matter searches
- Data Acquisition and Readout System for the LUX Dark Matter Experiment
- 3D Modeling of Electric Fields in the LUX Detector
- Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
- Iterative reconstruction of the detector response for medical gamma cameras
Cited by in corpus (26)
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
- Investigation of background electron emission in the LUX detector
- XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
- The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
- Search for annual and diurnal rate modulations in the LUX experiment
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Projected sensitivity of the LUX-ZEPLIN experiment to the decay of Xe
- Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
- SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
- Extending light WIMP searches to single scintillation photons in LUX
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- New constraints on ultraheavy dark matter from the LZ experiment
- First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data
- High-resolution spectroscopy of gaseous Kr conversion electrons with the KATRIN experiment
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
- Machine Learning Accelerated Likelihood-Free Event Reconstruction in Dark Matter Direct Detection
- Horizontal Position Reconstruction in PandaX-II
- Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
- Proposal of a Geiger-type Single-Phase Liquid Xenon Time Projection Chamber as Potential Detector Technique for Dark Matter Direct Search
- Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
- Search for two neutrino double electron capture of Xe and Xe in the full exposure of the LUX detector
- Position reconstruction and surface background model for the PandaX-4T detector