Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
arXiv:1403.1299 · doi:10.1016/j.astropartphys.2014.07.009
Abstract
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is ~events~keV~kg~day in a 118~kg fiducial volume. The observed background rate is ~events~keV~kg~day, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
18 pages, 12 figures / 17 images, submitted to Astropart. Phys
References in corpus (7)
- A direct empirical proof of the existence of dark matter
- The Large Underground Xenon (LUX) Experiment
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Evaluation of (alpha,n) Induced Neutrons as a Background for Dark Matter Experiments
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- ACTIVIA: Calculation of Isotope Production Cross-sections and Yields
- Study of a zirconium getter for purification of xenon gas
Cited by in corpus (23)
- Results from a search for dark matter in the complete LUX exposure
- Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
- Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Cosmogenic production of tritium in dark matter detectors
- Cosmogenic activation of materials
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- Material Screening with HPGe Counting Station for PandaX Experiment
- Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal
- Cosmogenic activation in double beta decay experiments
- Measurements of gamma ray, cosmic muon and residual neutron background fluxes for rare event search experiments at an underground laboratory
- Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
- Antineutrino sensitivity at THEIA
- Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
- Krypton and radon background in the PandaX-I dark matter experiment
- Radon Mitigation for the SuperCDMS SNOLAB Dark Matter Experiment
- Screener3D: a Gaseous Time Projection Chamber for Ultra-low Radioactive Material Screening
- Study of neutron-induced background and its effect on the search of 0 decay in
- Signatures of muonic activation in the Majorana Demonstrator
- AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
- The LUX direct dark matter search experiment
- Light yield and field dependence measurement in PandaX-II dual-phase xenon detector