Design and Commissioning of the PandaX-4T Cryogenic Distillation System for Krypton and Radon Removal
arXiv:2012.02436 · doi:10.1088/1748-0221/16/07/P07046
Abstract
An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is expected to be reduced by 7 orders of magnitude with 99% xenon collection efficiency at a flow rate of 10 kg/h by design. The same system can reduce radon content in xenon by reversed operation, with an expected radon reduction factor of about 1.8 in PandaX-4T under a flow rate of 56.5 kg/h. The commissioning of this system was completed, with krypton and radon operations tested under respective working conditions. The krypton concentration of the product xenon was measured with an upper limit of 8.0 ppt.
arXiv comment18 pages, 12 figures
References in corpus (21)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Results from 225 Live Days of XENON100 Data
- First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
- The XENON100 Dark Matter Experiment
- Dark matter direct search sensitivity of the PandaX-4T experiment
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- XMASS detector
- Results of Dark Matter Search using the Full PandaX-II Exposure
- Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
- Distillation of Liquid Xenon to Remove Krypton
- Removing krypton from xenon by cryogenic distillation to the ppq level
- Low-mass dark matter search results from full exposure of PandaX-I experiment
- A direct dark matter search in XMASS-I
- Online Rn removal by cryogenic distillation in the XENON100 experiment
- Chromatographic separation of radioactive noble gases from xenon
- Detection of krypton in xenon for dark matter applications
- Rn emanation measurements for the XENON1T experiment
- Material Screening with HPGe Counting Station for PandaX Experiment
- Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
- Constraining Radon Backgrounds in LZ
Cited by in corpus (10)
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- Dark Matter Search Results from 1.54 TonneYear Exposure of PandaX-4T
- Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
- Design, construction and commissioning of a high-flow radon removal system for XENONnT
- Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon
- Cosmogenic production of Ar in the context of the LUX-ZEPLIN experiment
- Proposal of a Geiger-type Single-Phase Liquid Xenon Time Projection Chamber as Potential Detector Technique for Dark Matter Direct Search
- Reduction of Rn-induced Backgrounds in a Hermetic Dual-Phase Xenon Time Projection Chamber
- Probing light mediators with recent PandaX-4T low energy electron recoil data
- Suppression of accidental backgrounds with deep neural networks in the PandaX-II experiment