Design, construction and commissioning of a high-flow radon removal system for XENONnT
arXiv:2205.11492 · doi:10.1140/epjc/s10052-022-11001-9
Abstract
A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT liquid xenon inventory of 8.4 tonnes at process flows up to 71 kg/h (200 slpm) is required to achieve a radon reduction by a factor two for radon sources inside the detector. To reach such high flows, the distillation column's design features liquid xenon inlet and outlets along with novel custom-made bath-type heat exchangers with high liquefaction capabilities. The distillation process was designed using a modification of the McCabe-Thiele approach without a bottom product extraction. The thermodynamic concept is based on a Clausius-Rankine cooling cycle with phase-changing medium, in this case the xenon itself. To drastically reduce the external cooling power requirements, an energy efficient heat pump concept was developed applying a custom-made four cylinder magnetically-coupled piston pump as compressor. The distillation system was operated at thermodynamically stable conditions at a process flow of (912) kg/h ((2586) slpm), 30 % over design. With this flow, a Rn activity concentration <1 Bq/kg is expected inside the XENONnT detector given the measured radon source distribution.
References in corpus (2)
Cited by in corpus (15)
- First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
- Search for New Physics in Electronic Recoil Data from XENONnT
- The XENONnT Dark Matter Experiment
- WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
- First Search for Light Dark Matter in the Neutrino Fog with XENONnT
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector
- Detector signal characterization with a Bayesian network in XENONnT
- Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory
- Characterization of a Rn source for low-energy electronic recoil calibration of the XENONnT detector
- Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System
- Study of radon removal performance of silver-ion exchanged zeolite from air for underground experiments
- Challenging Spontaneous Quantum Collapse with XENONnT
- Design Challenges for a Future Liquid Xenon Observatory
- Flow and thermal modelling of the argon volume in the DarkSide-20k TPC