Cryogenic bath-type heat exchangers for ultra-pure noble gas applications
arXiv:2203.01026 · doi:10.1088/1748-0221/17/05/P05037
Abstract
Two cryogenic bath-type heat exchangers for ultra-pure noble gas applications were developed with particular emphasis on noble gas liquefaction in cryogenic distillation systems. The main objective was to construct heat exchangers for xenon from materials that do not emanate radon and that fulfill ultra-high vacuum standards. Therefore, only high-quality copper and stainless steel materials were used. Especially, large-area oxygen-free copper fins with high conductivity in a new design ensure efficient heat transfer. One bath-type Xe-Xe heat exchanger was designed with a diameter of 50 cm to achieve a xenon condensing capacity of at least 100 kg/h. In order to guarantee the necessary heat transfer between the two xenon reservoirs, this heat exchanger features a specially manufactured stainless steel flange with a copper plate welded inside. We first tested our concept on a dedicated bath-type heat exchanger with a reduced diameter of 30 cm using liquid nitrogen to liquefy the xenon. A model based on conservative assumptions such as film boiling on the nitrogen side and film condensation on the xenon side was developed and applied to caluclate the expected heat transfer for our design. We were able to demonstrate an adjustable xenon liquefaction rate of up to 113 kg/h limited only by our measurement procedure at a cooling efficiency of for the LN-Xe heat exchanger.
References in corpus (22)
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- DARWIN: towards the ultimate dark matter detector
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- The XENON1T Dark Matter Experiment
- Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
- Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector
- The LUX-ZEPLIN (LZ) Experiment
- Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
- NEXO: Neutrinoless double beta decay search beyond year half-life sensitivity
- First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
- The MEG detector for decay search
- Online Rn removal by cryogenic distillation in the XENON100 experiment
- Investigation of radioactivity-induced backgrounds in EXO-200
- Rn emanation measurements for the XENON1T experiment
- Operation and performance of the ICARUS-T600 cryogenic plant at Gran Sasso underground Laboratory
- Radon and material radiopurity assessment for the NEXT double beta decay experiment
- PETALO: a Time-of-Flight PET with liquid xenon
- Constraining Radon Backgrounds in LZ
- Measurement of the onset of nucleate boiling in liquid xenon
- Liquid Argon Ionization Detector for Double Beta Decay Studies
- Ultra-clean radon-free four cylinder magnetically-coupled piston pump