1.6k citations · 3.1k across the 19 of their papers we have counts for
19 papers
Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
J. R. Verbus, C. A. Rhyne, D. C. Malling +12
We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galact…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +99
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection ch…
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
LUX Collaboration, D. S. Akerib, H. M. Araújo +99
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\ti…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…
FPGA-based Trigger System for the LUX Dark Matter Experiment
D. S. Akerib, H. M. Araujo, X. Bai +100
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
D. S. Akerib, H. M. Araujo, X. Bai +77
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds i…
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
M. Szydagis, D. S. Akerib, H. M. Araujo +77
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive di…
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
LUX Collaboration, D. S. Akerib, H. M. Araujo +100
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and…
Dark Matter Search Backgrounds from Primordial Radionuclide Chain Disequilibrium
D. C. Malling, S. Fiorucci, M. Pangilinan +4
Dark matter direct-detection searches for weakly interacting massive particles (WIMPs) are commonly limited in sensitivity by neutron and gamma backgrounds from the decay of radioa…
The Large Underground Xenon (LUX) Experiment
D. S. Akerib, X. Bai, S. Bedikian +91
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMP…
Technical Results from the Surface Run of the LUX Dark Matter Experiment
LUX Collaboration, D. S. Akerib, X. Bai +64
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lea…
The LUX Prototype Detector: Heat Exchanger Development
D. S. Akerib, X. Bai, S. Bedikian +47
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble elemen…
An Ultra-Low Background PMT for Liquid Xenon Detectors
D. S. Akerib, X. Bai, E. Bernard +64
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diam…
Radio-assay of Titanium samples for the LUX Experiment
D. S. Akerib, X. Bai, S. Bedikian +63
We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construct…
LUXSim: A Component-Centric Approach to Low-Background Simulations
D. S. Akerib, X. Bai, S. Bedikian +60
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been…
After LUX: The LZ Program
D. C. Malling, D. S. Akerib, H. M. Araujo +71
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 to…
Data Acquisition and Readout System for the LUX Dark Matter Experiment
D. S. Akerib, X. Bai, S. Bedikian +60
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are pro…
Status of the LUX Dark Matter Search
S. Fiorucci, D. S. Akerib, S. Bedikian +44
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of desi…