Analysis of backgrounds for the ANAIS-112 dark matter experiment
arXiv:1812.01377 · doi:10.1140/epjc/s10052-019-6911-4
Abstract
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, is taking data smoothly in "dark matter search" mode since August, 2017, after a commissioning phase and operation of the first detectors during the last years in various setups. A large effort has been carried out withinANAIS to characterize the background of sodium iodide detectors, before unblinding the data and performing the first annual modulation analysis. Here, the background models developed for all the nine ANAIS-112 detectors are presented. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities independently estimated following several approaches. In the region from 1 to 6 keVee the measured, efficiency corrected background level is 3.58+-0.02 keV-1 kg-1 day-1; NaI crystal bulk contamination is the dominant background source being 210Pb, 40K, 22Na and 3H contributions the most relevant ones. This background level, added to the achieved 1 keVee analysis threshold (thanks to the outstanding light collection and robust filtering procedures developed), allow ANAIS-112 to be sensitive to the modulation amplitude measured by DAMA/LIBRA, and able to explore at three sigma level in 5 years the WIMP parameter region singled out by this experiment.
arXiv commentFinal version for publication
References in corpus (34)
- Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
- Final model independent result of DAMA/LIBRA-phase1
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
- The DAMA/LIBRA apparatus
- Annual Modulation of Dark Matter: A Review
- Dark Matter Search Results from the PICO-60 CF Bubble Chamber
- First model independent results from DAMA/LIBRA-phase2
- Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
- Initial Performance of the COSINE-100 Experiment
- An experiment to search for dark matter interactions using sodium iodide detectors
- Limits on WIMP cross-sections from the NAIAD experiment at the Boulby Underground Laboratory
- Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
- The background in the neutrinoless double beta decay experiment GERDA
- First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17
- Background model for the NaI(Tl) crystals in COSINE-100
- Background studies for the EDELWEISS dark matter experiment
- Performance of ANAIS-112 experiment after the first year of data taking
- Investigation of radioactivity-induced backgrounds in EXO-200
- Search for annual and diurnal rate modulations in the LUX experiment
- Cosmogenic radionuclide production in NaI(Tl) crystals
- Preliminary results of ANAIS-25
- Assessment of backgrounds of the ANAIS experiment for dark matter direct detection
- Understanding NaI(Tl) crystal background for dark matter searches
- Results from the first cryogenic NaI detector for the COSINUS project
- DAMA/LIBRA-phase2 in WIMP effective models
- Cosmogenic production of tritium in dark matter detectors
- ANAIS-112 sensitivity in the search for dark matter annual modulation
- Monte Carlo simulation of the SABRE PoP background
- Neutron background at the Canfranc Underground Laboratory and its contribution to the IGEX-DM dark matter experiment
- Light yield determination in large sodium iodide detectors applied in the search for dark matter
- High Energy Activation Data Library (HEAD-2009)
- Analysis of the 40K contamination in NaI(Tl) crystals from different providers in the frame of the ANAIS project
- Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module
Cited by in corpus (36)
- First results on dark matter annual modulation from ANAIS-112 experiment
- Annual modulation results from three-year exposure of ANAIS-112
- Annual Modulation in Direct Dark Matter Searches
- Exploring coherent elastic neutrino-nucleus scattering using reactor electron antineutrinos in the NEON experiment
- Development of ultra-pure NaI(Tl) detectors for the COSINE-200 experiment
- Direct Detection of Dark Matter -- APPEC Committee Report
- ANAIS-112 sensitivity in the search for dark matter annual modulation
- Characterization of SABRE crystal NaI-33 with direct underground counting
- An induced annual modulation signature in COSINE-100 data by DAMA/LIBRA's analysis method
- Growth of Ultra-high Purity NaI(Tl) Crystal for Dark Matter Searches
- Review on dark matter searches
- Study of cosmogenic radionuclides in the COSINE-100 NaI(Tl) detectors
- ANAIS-112 status: two years results on annual modulation
- Annual modulations from secular variations: relaxing DAMA?
- Improving ANAIS-112 sensitivity to DAMA/LIBRA signal with machine learning techniques
- Cosmogenic activation in double beta decay experiments
- Performance of an ultra-pure NaI(Tl) detector produced by an indigenously-developed purification method and crystal growth for the COSINE-200 experiment
- Study on NaI(Tl) crystal at -35 C for dark matter detection
- Performance of the SABRE detector module in a purely passive shielding
- Combined Annual Modulation Dark Matter Search with COSINE-100 and ANAIS-112
- Study of cosmogenic activation above ground for the DarkSide-20k experiment
- Inelastic Dark Matter and the SABRE Experiment
- The SABRE South Technical Design Report Executive Summary
- Cosmogenic activation of sodium iodide
- Zone refining of ultra-high purity sodium iodide for low-background detectors
- Double Beta Decay Experiments at Canfranc Underground Laboratory
- Machine-learning techniques applied to three-year exposure of ANAIS-112
- Towards a Robust Model-Independent Test of the DAMA/LIBRA Dark Matter Signal: ANAIS-112 Results with Six Years of Data
- Influence of NaI background and mass on testing the DAMA modulation
- The role of small scale experiments in the direct detection of dark matter
- Long term measurement of the Rn concentration in the Canfranc Underground Laboratory
- AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
- Small scale direct dark matter search experiments
- Background model of the ANAIS-112 dark matter experiment
- Background stability and annual modulation test using PICOLON ultra-pure NaI(Tl) detector
- State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions