Long term measurement of the Rn concentration in the Canfranc Underground Laboratory
arXiv:2203.13978 · doi:10.1140/epjc/s10052-022-10859-z
Abstract
We report the results of six years (2013-2018) of measurements of Rn air concentration, relative humidity, atmospheric pressure and temperature in the halls A, B and C of the Canfranc Underground Laboratory (LSC). We have calculated all the Pearson correlation coefficients among these parameters and we have found a positive correlation between the Rn concentration and the relative humidity. Both correlated variables show a seasonal periodicity. The joint analysis of laboratory data and four years (2015-2018) of the meteorological variables outside the laboratory shows the correlation between the Rn concentration and the outside temperature. The collected information stresses the relevance of designing good Rn-mitigation strategies in current and future experiments at LSC; in particular, we have checked for two years (2017-2018) the good performance of the mitigation procedure of the ANAIS--112 experiment. Finally, in another measurement (2019-2021) for two years of live time, we report an upper limit to the residual Rn content of the radon-free air provided by the radon abatement system installed in the laboratory.
References in corpus (8)
- First results on dark matter annual modulation from ANAIS-112 experiment
- Annual modulation results from three-year exposure of ANAIS-112
- The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches
- Radon Daughter Plate-out Measurements at SNOLAB for Polyethylene and Copper
- Observation of annual modulation induced by rays from (, ) reactions at the Soudan Underground Laboratory
- Comparisons of annual modulations in MINOS with the event rate modulation in CoGeNT
- First results from the HENSA/ANAIS collaboration at the Canfranc Underground Laboratory
- DArT, a detector for measuring the 39Ar depletion factor