3D Modeling of Electric Fields in the LUX Detector
arXiv:1709.00095 · doi:10.1088/1748-0221/12/11/P11022
Abstract
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were built on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to C/m. From our studies, we deduce that the electric field magnitude varied while the mean value of the field of ~V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.
References in corpus (1)
Cited by in corpus (24)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Search for New Physics in Electronic Recoil Data from XENONnT
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- The XENONnT Dark Matter Experiment
- Investigation of background electron emission in the LUX detector
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Search for annual and diurnal rate modulations in the LUX experiment
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
- Kr calibration of the 2013 LUX dark matter search
- Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
- Position Reconstruction in LUX
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- Simulation of gain stability of THGEM gas-avalanche particle detectors
- Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
- Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
- Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
- Design and performance of the field cage for the XENONnT experiment
- Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
- / production and cross-section measurement with 3.4 MeV and 20 MeV proton beams
- Search for two neutrino double electron capture of Xe and Xe in the full exposure of the LUX detector
- Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
- Preparation and measurement of an Ar source for liquid xenon detector calibration