The XENON100 exclusion limit without considering Leff as a nuisance parameter
arXiv:1203.6823 · doi:10.1103/PhysRevD.86.015027
Abstract
In 2011, the XENON100 experiment has set unprecedented constraints on dark matter-nucleon interactions, excluding dark matter candidates with masses down to 6 GeV if the corresponding cross section is larger than 10^{-39} cm^2. The dependence of the exclusion limit in terms of the scintillation efficiency (Leff) has been debated at length. To overcome possible criticisms XENON100 performed an analysis in which Leff was considered as a nuisance parameter and its uncertainties were profiled out by using a Gaussian likelihood in which the mean value corresponds to the best fit Leff value smoothly extrapolated to zero below 3 keVnr. Although such a method seems fairly robust, it does not account for more extreme types of extrapolation nor does it enable to anticipate on how much the exclusion limit would vary if new data were to support a flat behaviour for Leff below 3 keVnr, for example. Yet, such a question is crucial for light dark matter models which are close to the published XENON100 limit. To answer this issue, we use a maximum Likelihood ratio analysis, as done by the XENON100 collaboration, but do not consider Leff as a nuisance parameter. Instead, Leff is obtained directly from the fits to the data. This enables us to define frequentist confidence intervals by marginalising over Leff.
arXiv comment10 pages;, 9 figures; references added
References in corpus (29)
- New results from DAMA/LIBRA
- Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
- Dark Matter Results from 100 Live Days of XENON100 Data
- Results from 730 kg days of the CRESST-II Dark Matter Search
- A search for light dark matter in XENON10 data
- Compatibility of DAMA/LIBRA dark matter detection with other searches
- Can annihilating Dark Matter be lighter than a few GeVs?
- Likelihood Approach to the First Dark Matter Results from XENON100
- Resolving astrophysical uncertainties in dark matter direct detection
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- XENON10/100 dark matter constraints in comparison with CoGeNT and DAMA: examining the Leff dependence
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- Toward A Consistent Picture For CRESST, CoGeNT and DAMA
- Can neutralinos in the MSSM and NMSSM scenarios still be light?
- A Model of Nuclear Recoil Scintillation Efficiency in Noble Liquids
- Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
- On the DAMA and CoGeNT Modulations
- Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
- New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
- DAMA and CoGeNT without astrophysical uncertainties
- Interplay between scintillation and ionization in liquid xenon Dark Matter searches
- Fundamental statistical limitations of future dark matter direct detection experiments
- Light Dark Matter in the light of CRESST-II
- Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
- Revisiting light neutralino scenarios in the MSSM
- A coherent understanding of low-energy nuclear recoils in liquid xenon
- Astrophysical limits on light NMSSM neutralinos
- Reconstructing signals from noisy data with unknown signal and noise covariance
- MIMAC potential discovery and exclusion of neutralinos in the MSSM and NMSSM
Cited by in corpus (7)
- Tools for model-independent bounds in direct dark matter searches
- Characterising dark matter searches at colliders and direct detection experiments: Vector mediators
- Quantifying the evidence for Dark Matter in CoGeNT data
- Regenerating WIMPs in the light of direct and indirect detection
- Probing the Supersymmetric Inflaton and Dark Matter link via the CMB, LHC and XENON1T experiments
- A New Method for Analysing Dark Matter Direct Detection Data
- Improving self-calibration