Analysis of Kr Prompt Scintillation Signals in the PIXeY Detector
arXiv:1911.03999 · doi:10.1088/1748-0221/15/01/P01023
Abstract
Prompt scintillation signals from Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (), notably its increase at low . In PIXeY data, the dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of , which can be attributed to processing effects and pulse overlap and one with a time constant of that increases in amplitude with electric drift field, the origin of which is not yet understood.
arXiv commentVersion edits: corrected typos and references, revised values presented in section 5.1, analysis conclusion is unchanged
References in corpus (16)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Calibration of a Liquid Xenon Detector with Kr-83m
- Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
- The ALICE Transition Radiation Detector: construction, operation, and performance
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Response of liquid xenon to Compton electrons down to 1.5 keV
- Calibration of a two-phase xenon time projection chamber with a Ar source
- Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
- Kr calibration of the 2013 LUX dark matter search
- Calibration of liquid argon and neon detectors with
- Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
- Modeling Pulse Characteristics in Xenon with NEST
- Field dependence of electronic recoil signals in a dual-phase liquid xenon time projection chamber
- A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers
- A Dual-phase Xenon TPC for Scintillation and Ionisation Yield Measurements in Liquid Xenon
- Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber
Cited by in corpus (5)
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- Characterization of alpha and beta interactions in liquid xenon
- Gamma-ray energies and intensities observed in decay chain //
- Light yield and field dependence measurement in PandaX-II dual-phase xenon detector