1.6k citations · 3.6k across the 25 of their papers we have counts for
25 papers
The Eos detector: a demonstrator of hybrid optical detection technology
Eos Collaboration, S. Arora, M. Askins +64
Eos is an R&D testbed for hybrid detector technologies, featuring state-of-the-art sub-ns photosensors, the first implementation of dichroicons in a large-scale demonstrator, and t…
Performance of the Eos detector with water
Eos Collaboration, S. Arora, M. Askins +64
In this manuscript we present the first results from Eos, a four tonne optical detector located at the University of California, Berkeley. The primary goal of Eos is to demonstrate…
EOS: a demonstrator of hybrid optical detector technology
T. Anderson, E. Anderssen, M. Askins +61
EOS is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With…
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
LUX Collaboration, D. S. Akerib, S. Alsum +94
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability…
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
J. Aalbers, D. S. Akerib, C. W. Akerlof +344
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dak…
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
LUX Collaboration, D. S. Akerib, S. Alsum +97
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This app…
Cosmogenic production of Ar in the context of the LUX-ZEPLIN experiment
J. Aalbers, D. S. Akerib, A. K. Al Musalhi +205
We estimate the amount of Ar produced in natural xenon via cosmic ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth's…
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
The LUX-ZEPLIN, Collaboration, : +194
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of Xe is presented. LZ is a 10-tonne xenon time projection ch…
Projected sensitivities of the LUX-ZEPLIN (LZ) experiment to new physics via low-energy electron recoils
The LZ Collaboration, D. S. Akerib, A. K. Al Musalhi +194
LUX-ZEPLIN (LZ) is a dark matter detector expected to obtain world-leading sensitivity to weakly interacting massive particles (WIMPs) interacting via nuclear recoils with a ~7-ton…
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
An Effective Field Theory Analysis of the First LUX Dark Matter Search
D. S. Akerib, S. Alsum, H. M. Araújo +94
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from partic…
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
The LUX Collaboration, D. S. Akerib, S. Alsum +90
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
D. S. Akerib, C. W. Akerlof, S. K. Alsum +175
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, So…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
Position Reconstruction in LUX
LUX Collaboration, D. S. Akerib, S. Alsum +91
The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…
First Searches for Axions and Axion-Like Particles with the LUX Experiment
D. S. Akerib, S. Alsum, C. Aquino +98
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xeno…
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +202
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. Th…
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
D. S. Akerib, S. Alsum, H. M. Araújo +98
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…
Results from a search for dark matter in the complete LUX exposure
D. S. Akerib, S. Alsum, H. M. Araújo +98
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experime…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Chromatographic separation of radioactive noble gases from xenon
LUX Collaboration, D. S. Akerib, H. M. Araújo +96
The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…
Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +99
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection ch…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…
FPGA-based Trigger System for the LUX Dark Matter Experiment
D. S. Akerib, H. M. Araujo, X. Bai +100
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…