Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers
arXiv:1801.07231 · doi:10.1016/j.astropartphys.2018.07.001
Abstract
Noble liquid radiation detectors have long been afflicted by spurious electron emission from their cathodic electrodes. This phenomenon must be understood and mitigated in the next generation of liquid xenon (LXe) experiments searching for WIMP dark matter or neutrinoless double beta decay, and in the large liquid argon (LAr) detectors for the long-baseline neutrino programmes. We present a systematic study of this spurious emission involving a series of slow voltage-ramping tests on fine metal wires immersed in a two-phase xenon time projection chamber with single electron sensitivity. Emission currents as low as A can thus be detected by electron counting, a vast improvement over previous dedicated measurements. Emission episodes were recorded at surface fields as low as 10 kV/cm in some wires and observed to have complex emission patterns, with average rates of 10-200 counts per second (c/s) and outbreaks as high as 10 c/s. A fainter, less variable type of emission was also present in all untreated samples. There is evidence of a partial conditioning effect, with subsequent tests yielding on average fewer emitters occurring at different fields for the same wire. We find no evidence for an intrinsic threshold particular to the metal-LXe interface which might have limited previous experiments up to fields of at least 160 kV/cm. The general phenomenology is not consistent with enhanced field emission from microscopic filaments, but it appears instead to be related to the quality of the wire surface in terms of corrosion and the nature of its oxide layer. This study concludes that some surface treatments, in particular nitric acid cleaning for stainless steel wires, can bringing about at least order-of-magnitude improvements in overall electron emission rates, and this should help the next generation of detectors achieve the required electrostatic performance.
arXiv comment16 pages, 15 figures
References in corpus (20)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- First Direct Detection Limits on sub-GeV Dark Matter from XENON10
- The XENON100 Dark Matter Experiment
- The Large Underground Xenon (LUX) Experiment
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- The XENON1T Dark Matter Experiment
- Liquid noble gas detectors for low energy particle physics
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- Two-Phase Emission Detector for Measuring Coherent Neutrino-Nucleus Scattering
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- Two distinct components of the delayed single electron background signals in liquid xenon emission detectors
- Response of photomultiplier tubes to xenon scintillation light
- Measurements of proportional scintillation and electron multiplication in liquid xenon using thin wires
- High Voltage in Noble Liquids for High Energy Physics
- Liquid Argon Dielectric Breakdown Studies with the MicroBooNE Purification System
- ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Cited by in corpus (21)
- The LUX-ZEPLIN (LZ) Experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- The XENONnT Dark Matter Experiment
- Investigation of background electron emission in the LUX detector
- Sources of Low-Energy Events in Low-Threshold Dark Matter and Neutrino Detectors
- A Dark Matter Interpretation of Excesses in Multiple Direct Detection Experiments
- Extending light WIMP searches to single scintillation photons in LUX
- First Search for Light Dark Matter in the Neutrino Fog with XENONnT
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon
- Prospects of charge signal analyses in liquid xenon TPCs with proportional scintillation in the liquid phase
- The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
- Waveform Simulation in PandaX-4T
- Study of dielectric breakdown in liquid xenon with the XeBrA experiment
- Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
- Unraveling the puzzle of slow components in gaseous argon of two-phase detectors for dark matter searches using Thick Gas Electron Multiplier
- GRANITE: Mechanical Characterization and Optical Inspection of Large-Area TPC Electrodes
- GRANITE: High-Resolution Imaging and Electrical Qualification of Large-Area TPC Electrodes
- State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions
- Material radiopurity control in the XENONnT experiment